Maintenance
Repairs
Danger!
Disconnect power before servicing or disassembling the housing or unit.
Never remove the front or end caps unless power is disconnected from the unit.
!
Caution!
Never open the casing of the camera. The camera itself does not contain any user-serviceable
parts. Ensure that all maintenance or repair work is performed only by qualified personnel. If
in doubt, contact your dealer's technical service center.
Bosch recommends that you contact your local Bosch service center for device maintenance
and repair. In the event of failure, the device should be removed from site for repair.
Replacement of the Mounting Cradle
1.
Disconnect power from the unit and, optionally, remove all connections.
2.
Using a 10 mm wrench or the multi-use tool, remove the three (3) M6 bolts holding the
mounting cradle to the mounting surface.
3.
Put the unit in a safe location.
4.
Using a 7 mm wrench or the multi-use tool, remove the seven (7) M4 bolts holding the
mounting cradle to the housing.
5.
Install a new mounting cradle in reverse of installation and tighten the seven (7) M4 bolts
to 2.0 N m (1.5 ft/lb).
6.
Finish installation as described in Mounting, page 24.
9
9.1
9.2
EXTEGRA IP 9000 FX
Maintenance | en
29
Bosch Security Systems
Installation Manual / Guide d'installation
2015.03 | 1.7 | F.01U.304.260