Reset: The reset button is used to reboot the system.
–
Power: The main power switch is used to apply or remove power from the power
supply to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system. Therefore, you must unplug
system before servicing.
Control panel LEDs
The control panel located on the front of the chassis has five LEDs. These LEDs provide you
with critical information related to different parts of the system. This section explains what
each LED indicates and any corrective action you may need to take.
–
Power failure: A flashing LED indicates a power failure in the power supply.
–
Overheat/fan fail: A flashing LED indicates a fan failure.
When continuously on (not flashing) the LED indicates an overheat condition, which may
be caused by cables obstructing the airflow in the system or the ambient room
temperature being too warm. Check the routing of the cables and make sure all fans are
present and operating normally. You should also check to make sure that the chassis
covers are installed. Finally, verify that the heat sinks are installed properly.
This LED will remain flashing or on as long as the fan failure/overheat condition exists.
–
NiC2: A flashing LED indicates network activity on GLAN2.
–
NIC1: A flashing LED indicates network activity on GLAN1.
–
HDD: A flashing LED indicates IDE channel activity in the SAS/SATA drive, SCSI
drive, and/or DVD-ROM drive activity.
–
Power: Indicates power is being supplied to the system's power supply units.
This LED should normally be illuminated when the system is operating.
Drive carrier LEDs
Your chassis uses SAS/SATA.
SAS/SATA drives
Each SAS/SATA drive carrier has two LEDs.
2.3.2
2.3.3