background image

Rack mounting instructions

This section provides information on installing the chassis into a rack unit. There are a variety
of rack units on the market, which may mean the assembly procedure will differ slightly. You
should also refer to the installation instructions that came with the rack unit you are using.

Notice!
This rail will fit a rack between 26" and 33.5" deep.

Separating the sections of the rack rails

The chassis package includes two rail assemblies in the rack mounting kit. Each assembly
consists of two sections:

an inner fixed chassis rail that secures directly to the chassis

an outer fixed rack rail that secures directly to the rack itself.

To separate the inner and outer rails:
1.

Locate the rail assembly in the chassis packaging.

2.

Extend the rail assembly by pulling it outward.

3.

Press the quick-release tab.

4.3

4.3.1

26

en | Rack installation

DIVAR IP 7000 2U

2013.09 | V2 | DOC

Installation Manual

Bosch Sicherheitssysteme GmbH

Содержание DIVAR DIP-7080-00N

Страница 1: ...DIVAR IP 7000 2U DIP 7080 00N DIP 7082 8HD en Installation Manual ...

Страница 2: ......

Страница 3: ...alling a fixed hard drive 17 3 4 Replacing or installing a DVD RW 18 3 5 Replacing the internal transcoder device 18 3 6 Replacing or installing the front port panel 18 3 7 Installing the motherboard 19 3 8 Installing the air shroud 19 3 9 Checking the air flow 20 3 10 Replacing the system fans 20 3 11 Power supply 21 3 11 1 Replacing the power supply 22 3 11 2 Replacing the power distributor 23 4...

Страница 4: ...theory 46 6 2 2 Multiple disks failed practice 50 6 2 3 Foreign configuration disk appears in the Windows GUI after booting 54 6 2 4 MegaCLI Commandline Utility 55 7 Additional documentation and client software 60 8 Appendices 61 8 1 Motherboard 61 8 1 1 Motherboard layout 61 8 1 2 Motherboard component overview 62 8 1 3 Motherboard features 64 8 1 4 Block diagram 66 8 2 Chipset overview 66 8 3 PC...

Страница 5: ...stribute the weight Always keep your back straight and lift with your legs Warning Interruption of mains supply Voltage is applied as soon as the mains plug is inserted into the mains socket However for devices with a mains switch the device is only ready for operation when the mains switch ON OFF is in the ON position When the mains plug is pulled out of the socket the supply of power to the devi...

Страница 6: ...is symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste In the EU separate collecting systems are already in place for used electrical and electronic products Please dispose of these devices at your local communal waste collection point or at a recycling center Electrical safety precautions Basic ele...

Страница 7: ...different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Do not use mats designed to decrease electrostatic discharge as prot...

Страница 8: ... or uneven surfaces may cause the cart unit combination to overturn Mount the unit per the manufacturer s instructions FCC and ICES compliance only for U S A and Canada This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the e...

Страница 9: ...rding straight out of the box Access to Bosch VMS After starting the system immediate access to the Bosch VMS management application is offered by a customized user interface The ability to use one central user interface for configuration and operation management reduces installation and training requirements and helps to keep ongoing system management costs low Chassis features The chassis includ...

Страница 10: ... unit can be placed in a rack for secure storage and use To setup your rack follow the step by step instructions included in this manual Power supply Each chassis model includes 2 high efficiency power supplies redundant In the unlikely event your power supply fails replacement is simple and can be accomplished without tools Air shroud Air shrouds are shields usually plastic which conduct the airf...

Страница 11: ...rd 6 2x NIC 3 2x USB 7 Slots for 1x graphic card 1x Display Port 1x DVI DVI port must be used for configuration 1x sound card 2x USB 2 0 4 Serial interface COM1 Control panel buttons There are two push buttons located on the front of the chassis These are in order from left to right a reset button and a power on off button 2 3 1 DIVAR IP 7000 2U System overview en 11 Bosch Sicherheitssysteme GmbH ...

Страница 12: ...y be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heat sinks are installed properly This LED will remain flashing or on as long as the fan failure overheat ...

Страница 13: ...ction to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED indicates a SAS SATA drive failure If one of the SAS SATA drives fail you should be notified by your system management software DIVAR IP 7000 2U System overview en 13 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 14: ...rews on each side of the cover which secure the cover to the chassis 2 Press the release tabs to remove the cover from the locked position Press both tabs at the same time 3 Once the top cover is released from the locked position slide the cover toward the rear of the chassis 4 Lift the cover off the chassis Notice Except for short periods of time do NOT operate the server without the cover in pla...

Страница 15: ...ve bays 1 Drive carrier 2 Dummy drive To remove hard drive trays from the chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the drive out of the chassis Notice Except for short periods of time swapping hard drives do not operate the unit with the hard drives removed from the bays 3 2 3 2 1 DIVAR IP 7000 2U Chassis setup and maint...

Страница 16: ...o the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 4 Secure the hard drive by tightening all 6 screws 1 Drive carrier 2 SAS SATA hard drive 5 Replace the drive carrier into the chassis bay Make sure that the drive carrier handle is completely closed 3 2 2 16 en Chassis setup and maintenance DIVAR IP 7000 2U 2013 09 V2 DOC Instal...

Страница 17: ...ude two open slots for an optional floppy drive and or hard disk drive s To utilize these slots the dummy drive and the slot cover must be removed To remove the dummy drive or hard disk drive 1 Disconnect the chassis from any power source 2 Press the release tab 3 Push against the back of the dummy drive sliding the dummy drive and slot cover forward out through the front of the chassis 4 Insert t...

Страница 18: ...ng tab at the rear left hand side when viewed from the front of the DVD drive Push the tab toward the drive and push the drive unit out the front of the chassis 5 Insert the new DVD drive in the slot until the tab locks in place 6 Reconnect the data and power cables 7 Replace the chassis cover replace the unit in the rack if necessary and turn on the system Replacing the internal transcoder device...

Страница 19: ... the unit out of the chassis 5 Insert the new front port panel unit in the slot until the tab locks into place 6 Connect the data and power cables to the backplane and motherboard Installing the motherboard Motherboard problems will be handled by trained support people only Installing the air shroud Air shrouds concentrate airflow to maximize fan efficiency The air shroud does not require screws t...

Страница 20: ...ed periodically 2 Do not operate the system without drives or drive trays in the drive bays Use only recommended material 3 Make sure no wires or foreign objects obstruct air flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs inform you about system status See also Installing the air shroud page 19 System interface page 10 Installi...

Страница 21: ... release tab to lift the failed fan from the chassis and pull it completely from the chassis 5 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans 6 Reconnect the power cord turn on the system and make sure that the fan is working properly before replacing the ...

Страница 22: ...e ordered directly from Bosch RMA desk To replace the power supply 1 Only for units with one power supply Turn off the unit and unplug the power cord 2 Push the release tab on the back of the power supply as illustrated 3 Pull the power supply out using the handle provided 4 Replace the failed power module with the same model 5 Push the new power supply module into the power bay until you hear a c...

Страница 23: ...r supplies 3 Locate the power distributor between the power supply and the fan row 4 Remove the three screws securing the power supply 5 Gently pull the power distributor from the chassis Gently guide all the cables through the power distributor housing 6 Slide the new power distributor module into the power distributor housing Make that you slide the cables through the bottom of the housing 7 Rec...

Страница 24: ...setup location Situate the system in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Place the system near a grounded power outlet Leave approximately 25 inches clearance in front of the rack to be able to open the front door completely Leave approximately 30 inches of clearance in the back of the rack to allow for suf...

Страница 25: ...n not servicing to maintain proper cooling See also Safety precautions page 5 Rack mounting considerations Ambient operating temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible...

Страница 26: ...eparating the sections of the rack rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the chassis an outer fixed rack rail that secures directly to the rack itself To separate the inner and outer rails 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembl...

Страница 27: ...r rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated 4 Repeat steps for the other inner rail extension Installing the outer rails to the rac...

Страница 28: ...ervicing Installing the chassis into the rack To install the chassis into a rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws...

Страница 29: ...ositioned with just enough space to accommodate the width of the Telco rack Finish by sliding the chassis into the rack and tightening the brackets to the rack Turning on the system The last thing to be done is to provide input power to the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and ...

Страница 30: ...a valid IP address range to be used with DIVAR IP and associated devices The default iSCSI settings are optimized for use with Bosch VMS VRM User with administrator rights User BVRAdmin Password WSS4Bosch Notice We strongly recommended not changing the user settings Changing the user settings can result in malfunctioning of the system Starting the Appliccation DIVAR IP system is ready to go out of...

Страница 31: ...ng the Bosch VMS Configuration Client Notice To perform administrative tasks the BVRAdmin account can be entered when Bosch VMS default screen is displayed To do so press CTRL ALT DEL then hold down SHIFT while clicking the Switch User option See also Using Configuration Wizard page 31 Using Bosch VMS Configuration Client page 42 Recovering the unit page 44 Using Configuration Wizard Intended use ...

Страница 32: ... through the following pages of the wizard Welcome page If the connection to the Management Server cannot be established a corresponding error message is displayed You cannot continue working with Configuration Wizard If VRM is not available on the computer a corresponding error message is displayed You cannot continue working with Configuration Wizard If the license check fails a corresponding er...

Страница 33: ...dresses automatically assigned to the device Certain applications VRM Bosch Video Management System Bosch Video Client Configuration Manager use the IP address for the unique assignment of the device If using these applications the DHCP server must support the fixed assignment between IP address and MAC address and must be appropriately set up so that once an IP address is assigned it is retained ...

Страница 34: ...Time settings page You configure the time settings of the operating system 34 en System setup first steps DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 35: ... displays the devices and services that are included in the latest saved configuration You can import a configuration DIVAR IP 7000 2U System setup first steps en 35 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 36: ...ices that are not included in the latest saved configuration Deselect the devices that should not be added to the configuration then click Next 36 en System setup first steps DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 37: ...ach camera individually Configuration Client must be used in order to set or change device passwords Password check is performed automatically when you do not enter a character in a password field for a few seconds or you click outside the password field DIVAR IP 7000 2U System setup first steps en 37 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 38: ...ding profile details All video devices use the default recording profile details To change these use the Bosch VMS Configuration Client Stream quality settings All video devices use the default settings for Stream 1 to record To change these use the Bosch VMS Configuration Client Schedule 38 en System setup first steps DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme Gm...

Страница 39: ...riday The Night schedule is active from 6 p m until 8 a m Monday through Friday The Weekend schedule is active 24 hours a day for Saturday and Sunday To change the schedule use the Bosch VMS Configuration Client DIVAR IP 7000 2U System setup first steps en 39 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 40: ...stops and the message appears that the internal iSCSI storage is not ready for recording because the LUNs are not formatted you must format the LUNs using Bosch VMS Configuration Client To format the LUNs see Bosch VMS Configuration Manual Chapter Formatting a LUN 40 en System setup first steps DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 41: ...ge You can add users and passwords Use Configuration Client to add user groups and to change permissions DIVAR IP 7000 2U System setup first steps en 41 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 42: ...arts 2 Enter the following then click OK User name admin Password no password required if not set with the wizard Connection 127 0 0 1 3 On the Hardware menu click Initial Device Scan The application performs a network scan for all defaulted devices 4 To assign all devices at once click Select All then right click the selected devices then click SetIP Addresses The Set IP Addresses dialog box is d...

Страница 43: ...n the image window with a red dot in the camera s icon are viewed live To verify recording functionality in the Operator Client 4 Cameras in the Logical Tree with a red dot in the camera s icon are recording To verify playback functionality in the Operator Client 4 The time line moves if the a camera is viewed in playback mode To perform further functionalities refer to the Bosch VMS manual Perfor...

Страница 44: ...ill damage the Recovery media 4 The unit starts from the Recovery media If the setup is successfull press Yes to restart the system 5 Windows performs the initial setup of the operating system The unit restarts after Windows has completed the setup 6 After the restart of the unit the factory default settings are installed and the Windows logon screen is displayed The factory default settings are I...

Страница 45: ...ler The data area of a disk is never used by this no matter how often you write and delete the RAID configuration New or Clear Configuration deletes the COD if available Save Configuration saves the new COD Initialize deletes the Disk Data OS DIVAR IP 7000 2U Recovering the unit en 45 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 46: ... 5 4 disks got from rebuild to offline no Hot Spare 2 disks online 2 disks missing 2 disks foreign configuration or unconfigured good The rebuild only could start when the other three disks were online before the rebuild disk is first fail degraded RAID was rebuilding Foreign disk is the second fail disk one of the disks from which the parity data was copied to the rebuilding disk before the crash...

Страница 47: ...l start at an appropriate sequence number minus a few hundred choose the number of events In this example we choose a start sequence 5800 from 6412 and all 612 events left We find a timestamp that PD Physical Drive 6 was removed PD 4 stops rebuilding Finally PD 4 is also removed DIVAR IP 7000 2U Recovering the unit en 47 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 48: ...AdpAliLog aAll evt txt but it takes a few minutes until the large file is written and it is too much information For example it is much better to use this commands create with f txt a file for analysis MegaCli AdpEventLog GetEvents warning f warning txt aALL Adapter 0 Number of Events 288 seqNum 0x00001875 Time Mon Jul 19 13 37 28 2010 Code 0x00000124 Class 1 Locale 0x20 Event Description Patrol R...

Страница 49: ...065 Class 2 Locale 0x02 Event Description Rebuild failed on PD 04 e0xfc s4 due to source drive error Event Data Device ID 4 Enclosure Index 252 Slot Number 4 seqNum 0x000018ba Time Mon Jul 19 14 12 25 2010 Code 0x000000fb Class 2 Locale 0x01 Event Description VD 00 0 is now DEGRADED Event Data Target Id 0 seqNum 0x000018bc Time Mon Jul 19 14 12 25 2010 Code 0x000000fb Class 2 Locale 0x01 Event Des...

Страница 50: ...t Description VD 00 0 is now OFFLINE Event Data Target Id 0 Adapter 0 Number of Events 288 seqNum 0x00001891 Time Mon Jul 19 13 52 41 2010 Code 0x000000fc Class 3 Locale 0x01 Event Description VD 01 1 is now OFFLINE Event Data Target Id 1 Multiple disks failed practice Press C to enter Utility Click start and scan disks You get to the foreign configuration import screen 6 2 2 50 en Recovering the ...

Страница 51: ...marked as not importable click Cancel and view Configuration 2 It is the same this means a complex situation requires manual interaction Click to clear all configurations ignore the warning DIVAR IP 7000 2U Recovering the unit en 51 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 52: ...fy the first failed disk In this example disk in Slot 4 was first fail Slot 7 second fail Click on second fail PD7 in the Logical View and you get in the Physical drive menu Choose replace missing PD and the correct row for Slot 7 drive and click go Ignore the warning 52 en Recovering the unit DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 53: ... in logical view we see disk online and a degraded RAID Click on disk 4 to get in the PD menu Click on correct row on Global or dedicated Hot Spare and on go Click on home in the Logical View the rebuild is starting DIVAR IP 7000 2U Recovering the unit en 53 Bosch Sicherheitssysteme GmbH Installation Manual 2013 09 V2 DOC ...

Страница 54: ... in the MSM GUI Click scan foreign configuration In the next window click clear foreign configuration An unconfigured good drive is displayed Right click this drive and choose a hotspare type You see the rebuild is starting at once 6 2 3 54 en Recovering the unit DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 55: ...DPatrolRead val DisableOCR val BootWithPinnedCache val AutoEnhancedImportEnbl AutoEnhancedImportDsbl aN a0 1 2 aALL ExposeEnclDevicesEnbl val aN a0 1 2 aALL DsblSpinDownHsp val aN a0 1 2 aALL SpinDownTime val aN a0 1 2 aALL MegaCli AdpSetProp AutoDetectBackPlaneDsbl val aN a0 1 2 aALL val 0 Enable Auto Detect of SGPIO and i2c SEP 1 Disable Auto Detect of SGPIO 2 Disable Auto Detect of i2c SEP 3 Di...

Страница 56: ...lDevicesEnbl DsblSpinDownHsp SpinDownTime PrCorrectUncfgdAreas aN a0 1 2 aALL DsblSpinDownHSP aN a0 1 2 aALL MegaCli AdpAllInfo aN a0 1 2 aALL MegaCli AdpGetTime aN a0 1 2 aALL MegaCli AdpSetTime yyyymmdd hh mm ss aN MegaCli AdpSetVerify f fileName aN a0 1 2 aALL MegaCli AdpBIOS Enbl Dsbl SOE BE Dsply aN a0 1 2 aALL MegaCli AdpBootDrive Set Lx physdrv E0 S0 Get aN a0 1 2 aALL MegaCli AdpAutoRbld E...

Страница 57: ...dArray Lx L0 1 2 Lall aN a0 1 2 aALL MegaCli LDInit Start full Abort ShowProg ProgDsply Lx L0 1 2 LALL aN a0 1 2 aALL MegaCli LDCC Start force Abort ShowProg ProgDsply Lx L0 1 2 LALL aN a0 1 2 aALL MegaCli LDBI Enbl Dsbl getSetting Abort ShowProg ProgDsply Lx L0 1 2 LALL aN a0 1 2 aALL MegaCli LDRecon Start rX Add Rmv Physdrv E0 S0 ShowProg ProgDsply Lx aN MegaCli LdPdInfo aN a0 1 2 aALL MegaCli L...

Страница 58: ...eName aN a0 1 2 aALL MegaCli AdpEventLog GetCCIncon f fileName LX L0 2 5 LALL aN a0 1 2 aALL MegaCli AdpEventLog Clear aN a0 1 2 aALL MegaCli AdpBbuCmd aN a0 1 2 aALL MegaCli AdpBbuCmd GetBbuStatus aN a0 1 2 aALL MegaCli AdpBbuCmd GetBbuCapacityInfo aN a0 1 2 aALL MegaCli AdpBbuCmd GetBbuDesignInfo aN a0 1 2 aALL MegaCli AdpBbuCmd GetBbuProperties aN a0 1 2 aALL MegaCli AdpBbuCmd BbuLearn aN a0 1 ...

Страница 59: ...iscardPreservedCache Lx L0 1 2 Lall aN a0 1 2 aALL MegaCli AdpInfoCompare checkFw string checkID hex checkBatt val checkDimm val aN a0 1 2 aALL MegaCli adpFwDump MegaCli AdpNameRtn aN a0 1 2 aALL sssssssssss It must be between eight and thirty two characters and contain at least one number one lowercase letter one uppercase letter and one non alphanumeric character kkkkkkkkkkk Must be less than 25...

Страница 60: ... region and your country select Product Catalog start a search for your product select the product in the search results to show the existing documents And on the following network share 4 IP address of DIVAR IP sources 7 60 en Additional documentation and client software DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 61: ...ayout Figure 8 1 Motherboard layout Important notes to the user Jumpers not indicated are for testing only When LE2 Onboard Power LED Indicator is on system power is on Unplug the power cable before installing or removing any components All systems have a SATA DOM connected to Serial ATA ports I SATA 5 with a small power connector DOM PWR SATA DOM Is plugged in connector I SATA 5 on the motherboar...

Страница 62: ...abled 42 JBT1 CMOS Clear 40 JPES Energy Saving Feature Pins 2 3 Disabled 13 14 JI2C1 JI2C2 SMB to PCI Slots 17 JPG1 Onboard VGA Enable Pins 1 2 Enabled 11 12 JPL1 JPL2 LAN1 LAN2 Enable Pins 1 2 Enabled 24 JPT1 TPM Enable Pins 1 2 Enabled 10 JPB BMC Jumper Pins 1 2 Enabled 8 1 2 62 en Appendices DIVAR IP 7000 2U 2013 09 V2 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Страница 63: ...21 I SATA 0 5 Serial ATA ports X8SIL has 4 Serial ATA Ports 2 IPMI IPMI LAN Port X8SIL F Only 35 JPI2C PWR supply I2C System Management Bus 31 SPKR1 Internal speaker buzzer 25 T SGPIO 0 1 Serial General Purpose IO headers for SATA 3 20 USB0 1 Backplane USB 0 1 19 USB 4 Type A USB Connector 18 USB 10 11 Front Panel USB header X8SIL F Only 22 DOM PWR Disk On Module DOM Power Connector 39 JTPM Truste...

Страница 64: ...Intel 82574L Gigabit 10 100 1000 Mb s Ethernet Controllers for LAN 1 and LAN 2 ports Two 2 RJ 45 Rear IO Panel Connectors with Link and Activity LEDs Single Realtek RTL8201N PHY to support IPMI 2 0 X8SIL F Only I O Devices SATA Connections X8SIL F X8SIL V Only SATA Ports Six 6 RAID Windows RAID 0 1 5 10 RAID Linux RAID 0 1 10 SATA Connections X8SIL Only SATA Ports Four 4 Integrated IPMI 2 0 X8SIL ...

Страница 65: ...er on mode for AC power recovery PC Health Monitoring CPU Monitoring Onboard voltage monitors for CPU core 3 3V 5V 12V 3 3V Stdby 5V Stdby VBAT HT Memory Chipset CPU 3 Phase switching voltage regulator CPU System overheat LED and control CPU Thermal Trip support Thermal Monitor 2 TM2 support Fan Control Fan status monitoring with firmware 4 pin Pulse Width Modulation fan speed control Low noise fa...

Страница 66: ...nality and the capability of the single chip Intel 3400 chipset the X8SIL X8SIL F X8SIL V motherboard provides the performance and feature set required for single processor based systems with configuration options optimized for entry level server platforms The high speed Direct Media Interface DMI featured in the Intel 3400 3420 chipset enables the X8SIL X8SIL F X8SIL V motherboard to offer a high...

Страница 67: ...fine the sensitivity of the voltage monitor by using SD III Fan status monitor with software PC health monitoring can check the RPM status of the cooling fans via Supero Doctor III CPU overheat LED and control This feature is available when the user enables the CPU overheat warning feature in the BIOS This allows the user to define an overheat temperature When this temperature reaches this pre def...

Страница 68: ...clock generator drive interface control logic and interrupt and DMA logic The wide range of functions integrated onto the Super I O greatly reduces the number of components required for interfacing with floppy disk drives The Super I O supports two 360 K 720 K 1 2 M 1 44 M or 2 88 M disk drives and data transfer rates of 250 Kb s 500 Kb s or 1 Mb s It also provides two high speed 16550 compatible ...

Страница 69: ...ton BMC communicates with onboard components via six SMBus interfaces fan control Platform Environment Control Interface PECI buses and General Purpose I O T SGPIO ports It also includes the following features One X Bus parallel interface for expansion I O connections Three ADC inputs Analog and Digital Video outputs Two serial for boundary scan and debug There are two different versions of the Nu...

Страница 70: ......

Страница 71: ......

Страница 72: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2013 ...

Отзывы: