The VD event reports first a degraded state, then an offline state. The "first failed" disk was
the rebuilding PD4. When PD6 failed, the rebuild stopped, when PD4 was gone, RAID gets
offline.
How to use the MegaCLI Command-Line Utility
Use a bootable DOS USB stick with XMS manager "himem.sys" and start the MegaCLI.exe.
Please see the command reference in MegaCLI Commandline Utility.
The whole amount of log events can be seen with MegaCLI –AdpAliLog –aAll > evt.txt; but it
takes a few minutes until the large file is written and it is too much information.
For example, it is much better, to use this commands
(create with "-f …txt" a file for analysis)
MegaCli -AdpEventLog -GetEvents -warning -f warning.txt -aALL
Adapter: 0 - Number of Events : 288
seqNum: 0x00001875
Time: Mon Jul 19 13:37:28 2010
Code: 0x00000124
Class: 1
Locale: 0x20
Event Description: Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD
with an active process, or are in an excluded VD
Event Data:
48