4.
Separate the inner rail extension from the outer rail assembly.
Installing the inner rails
The chassis includes a set of inner rails in two sections: inner rails and inner rail extensions.
The inner rails are pre-attached to the chassis, and do not interfere with normal use of the
chassis if you decide not to use a server rack. The inner rail extension is attached to the inner
rail to mount the chassis in the rack.
1
2
3
To install the inner rails:
1.
Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis
with the rail extension holes. Make sure the extension faces "outward" just like the pre-
attached inner rail.
2.
Slide the extension toward the front of the chassis.
3.
Secure the chassis with 2 screws as illustrated.
4.
Repeat steps for the other inner rail extension.
Installing the outer rails to the rack
Outer rails attach to the rack and hold the chassis in place. The outer rails extend between 30
inches and 33 inches.
1
2
3
4.3.2
4.3.3
DIVAR IP 7000 2U
Rack installation | en
27
Bosch Sicherheitssysteme GmbH
Installation Manual
2013.09 | V2 | DOC