DIVAR IP 7000 (3U)
System overview | en
15
Bosch Sicherheitssysteme GmbH
Installation Manual
2016.08 | V2.1 | DOC
9
Drive carrier LEDs (green: access to
this drive/red: drive failure)
LED color
Blinking pattern
Behavior for device
ActivityLED
Blue
Solid On
SAS drive installed
Blue
Blinking
I/O activity
StatusLED
Red
Solid On
Failed drive for SATA/NVMe with
RSTe support
Red
Blinking at 1 Hz
Rebuild drive for SATA with RSTe
support
Red
Blinking with two
blinks and one stop
at 1 Hz
Hot spare for SATA with RSTe
support
Red
On for five seconds,
then off
Power on for SATA with RSTe
support
Red
Blinking at 4 Hz
Identify drive for SATA with RSTe
support
Rear view:
1
5
9
2
6
3
7
4
8
1
2x power supply modules
2
2x redundant SSD drives for operating
system (RAID1 mirror)
3
1x serial port
4
1x network port for BMC (Baseboard
Management Controller) connection
and IPMI (Intelligent Platform
Management Interface) monitoring
5
4 USB ports
(2x USB 2.0 and 2x USB 3.0)
6
2x network ports for data transmission
(teamed)
Note:
Do not change the teaming
mode!