D9412GV2/D7412GV2
|
Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A
74
Bosch Security Systems, Inc. | 7/09 | F01U003641-04
Figure 43: D7412GV2, SDI Devices
+
-
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
NFPA
Style 3.5
Signaling
Line
Circuits
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
NFPA
Style 3.5
Signaling
Line
Circuits
NOT USED
25
NOT USED
ZONEX POWER +
ZONEX COMMON
26
24
23
GRN
Point 8
S3 Option
Closed = 1K
Ω
EOL
Normal Operation
Open =AB-12 UL
Bell Box 220 K
Ω
D5200/D5360
PROG CONN
D7412GV2
1 - Up to eight supervised D1255RB, D1256RB,
D1255, D1256, D1260B, or D1260 Keypads, or
D1257RB or D1257 Fire Annunciators
2 - Up to 8 D9210B Access Control Interface
Modules
3 - Up to 1 supervised 9131A Parallel Printer
Interface Module, or other SDI device
4 - Power limited, supervised
5
D9133TTL-E or DX4020 Network Interface
Module or other SDI device
6 - D8125 POPEX No.1
7 - Up to 67 D9127U/T POPITs or up to 63
D8127U/T POPITs
8 - Zonex 1: Up to 9 D8128Ds
9-
Zonex 1: Up to 8 D8129s maximum
* The number of D8129 OctoRelays that can be connected to each zonex terminal on the control panel is limited by the number of
D8128D OctoPOPITs connected to the same terminal. Refer to the
D8128D Installation Guide
(P/N: 41242) or the
D8129 Operation
and Installation Guide
(P/N: 74-04562-000) for specific information.
Do not
connect the D9131A to systems that require commercial fire listings. The electrical ground
on the D9131A does not isolate earth ground.
All external connections except Terminal 5 (battery positive) are power limited.