D9412GV2/D7412GV2
|
Operation and Installation Guide | 13.0 Programmer and Accessory Connections
66
Bosch Security Systems, Inc. | 7/09 | F01U003641-04
13.0 Programmer and
Accessory Connections
13.1 Programmer
Connector
Refer to the
D5200 Operation Manual
(P/N: 74-06176-000) for complete information on
using the D5200 programmer.
To connect and disconnect the programmer:
1. Lock the Reset Pin (
Figure 34
).
2. Connect the D5200 Data/Power cord to the
programming connector on the control panel
(
Figure 35
).
3. Perform the desired programming function (send
or receive program).
4. Disconnect the programmer.
Figure 34: Reset Pin
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
32
31
30
29
1
2
1 - Reset Pin locked (closed)
2 - Reset Pin normal (open) for normal control
panel operation
13.2 Programmer Access Reports
When a program is sent to the control panel, the
control panel sends a Prog Access OK report 10
seconds after the handler exits or when the
programmer disconnects. The prompt in routing must
be programmed
Yes
to send this report.
13.3 Accessory
Connector
Use the accessory connector to connect the control
panel to the D928 Dual Phone Line Switcher. The
accessory connector is on the bottom right corner of
the I/O board (
Figure 35
). The D928 lets the control
panel use two telephone lines to send reports.
Refer to
Section 7.11 D928 Dual Phone Line Switcher
on page 32 for installation and operating instructions.
Figure 35: Programmer and Accessory
Connections