background image

 

D621 Series 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 

User's Guide 

LED Keypad 

Содержание D621 Series

Страница 1: ...D621 Series EN User s Guide LED Keypad ...

Страница 2: ...hat the central station is not able to receive the report your phone may be unavailable for up to 20 minutes while the panel makes additional communication attempts Figure 1 Information Box MY SECURITY COMPANY IS CALL BEFORE TEST ____________________________ THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER ____________________________________ THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHO...

Страница 3: ...ire Alarms 14 Burglary Alarms 14 Trouble Events 14 How Your System Reports Alarms 15 Silence Alarms 15 Keypad Adjust Cmd 49 16 Log Out Of The System 16 Turn the System Off 17 Turn The System All On All On or Cmd 1 18 Turn The System Part On Part On or Cmd 2 20 Turn The System Part 2 On Cmd 3 21 Set Part 2 Points Cmd 65 23 Turn The System On With No Delay 24 Turn The System On With No Exit Tone 24 ...

Страница 4: ...ouble Cmd 48 41 System Test Cmd 41 42 Walk Test Cmd 44 44 Reset The System Cmd 47 45 Turn Watch On Off Cmd 61 45 Select Watch Tone Cmd 62 46 Select Watch Points Cmd 63 48 Extend Auto On Time Cmd 51 49 All Areas On Cmd 80 50 All Areas Off Cmd 81 51 Auto Forward On Off Cmd 82 51 Remote Arming With Telephone Area 1 52 Remote Program Cmd 43 53 Security System Limitations 53 Fire Safety And Evacuation ...

Страница 5: ...ps to secure life property and investments against fire theft and bodily harm It consists of one or more keypads motion sensors such as detectors or devices located on doors and windows and sensing devices designed to detect the presence of smoke or combustion Each device is connected to a sophisticated control panel with a microprocessor which processes all events registered by the system Control...

Страница 6: ...621 D621B Front Panel Features 1 A B C 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Part All Cmd Status Tes t Syste m Weekly Check Cha nge Watch Areas 4 9981 5297 9A 1 2 3 4 D621 D621B 2 1 3 4 1 Sounder 2 Point status indicators 3 All On and Part On indicators 4 Status and Cmd indicators ...

Страница 7: ...ted point has returned to normal the point indicator on the Keypad turns off Are All Points The Same Not all points are the same In fact there are two basic types of points Controlled and 24 Hour Controlled Points Controlled Points respond to alarm conditions depending upon whether the system is turned on or off They are programmed to either respond instantly to alarm conditions or to provide a de...

Страница 8: ... turned off Non Fire Points Monitors non fire detection devices They are always on and cannot be turned off All On When you turn your system All On refer to Figure 3 you are turning on all controlled points both interior motion detectors and perimeter doors and windows of the building Figure 3 Controlled Points are All On 1 2 3 4 4 4 1 Dining room 2 Living room 3 Kitchen 4 Bedroom ...

Страница 9: ...ar points included in this portion are determined by your security company Part points may include only the perimeter doors and windows of your system or the points on the first floor of a two story house Check with your security company to learn which points are Part points Figure 4 Controlled Points are Part On 1 2 3 4 4 4 5 6 1 Dining room 2 Living room 3 Kitchen 4 Bedroom 5 controlled point 6 ...

Страница 10: ...ng the system All On Part On Lets you turn your system Part On Refer to Turning the system Part On No Delay Lets you turn your system All On or Part On without entry or exit delay Refer to Turning the system on with no delay Table 1 Keypad Keys continued Key Function Bypass Lets you bypass one or more points Refer to Bypass points When available advances to the next display A B C Emergency functio...

Страница 11: ...the duration of the time set by your security company Table 2 Keypad Tones continued Tone Tone Pattern Description Exit Delay Error Objects cannot be created from editing field codes After you turn your system on the keypad emits an intermittent beep and counts down the Exit Delay time If you do not exit before the exit delay time expires and an Exit Delay point is faulted an alarm event begins En...

Страница 12: ...ed Watched Tone Refer to Select watch tone Keypad LED Descriptions Table 3 describes the keypad LEDs Table 3 Keypad LED Descriptions LED Status Description On No system troubles Slow Flash AC failure system trouble or keypad was moved away from its assigned area Status Fast Flash keypad in Command Mode System Test was initiated Off User logged off and no command is active Fast Flash Waiting for pa...

Страница 13: ... Delay Off Panel disarmed or armed All On Slow Flash Panel armed Part On Part 2 On with No Delay Part On Panel armed Part On Part 2 On with Entry Exit Delay Commands Commands allow you to carry out various tasks such as add or delete passcodes set the date and time or test the system Each command is detailed throughout this user guide Commands are written as Cmd 6 3 To enter this command first pre...

Страница 14: ...or smoke or fire Make sure all occupants know the difference between the Burglary Alarm tone and the Fire Alarm tone Burglary Alarms Burglary alarms are the second priority When a burglary point activates your keypad emits a Burglary Alarm tone Ensure all occupants know the difference between the Burglary Alarm tone and the Fire Alarm tone refer to Table 2 on page 11 The keypad display shows each ...

Страница 15: ...or more information on determining the nature of the trouble If your telephone service is interrupted your security system cannot send reports to your security company unless it has an alternate means of transmitting them Silence Alarms When there is an alarm the alarm tone sounds and the point s in alarm illuminate on the display If you enter your passcode before the system dials your security co...

Страница 16: ... Press Cmd 4 9 Enter your passcode if necessary 2 To adjust the keypad sounder volume press and hold the key and then press 1 to increase the volume or 4 to decrease the volume 3 Press Cmd to exit this command function when all adjustments are made Log Out Of The System The system remembers passcodes entered for approximately 10 seconds after you have stopped pressing keys To log out of the system...

Страница 17: ... turn the system off If you enter through the wrong door or fail to turn the system off before the entry delay time expires you may cause an alarm If an alarm occurs silence the alarm by entering your passcode and call your security company to let them know it is not an emergency situation 1 When the system is All On the keypad illuminates the All On indicator If the system is either Part On or Pa...

Страница 18: ...turn on the entire system Once you press the All On key the Exit Delay timer starts its countdown Your security company programs the length of exit delay time to ensure you have adequate time to exit You should leave the premises before the exit time expires Leaving after exit delay expires starts an alarm event 1 Make sure all points are normal not faulted If your system has a faulted point retur...

Страница 19: ...y stop the system from turning on by entering your passcode If you wish you can turn the system All On with No Delay refer to Section Turn The System On With No Delay on page 24 by pressing No Delay or you may bypass points by pressing Bypass Refer to Bypass Points on page 27 for more information 4 During the last 10 seconds of Exit Delay the Exit Delay tone becomes more urgent warning you not to ...

Страница 20: ...he premises before the exit time expires Leaving after exit delay expires starts an alarm event 1 Make sure Part points are normal not faulted 2 Press Part On The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode if necessary The Part On Status and Cmd indicators light Figure 9 If your system has a faulted point door or window open you can either c...

Страница 21: ...o I cannot perform this command You have __________ second s to exit premises before the system turns on Part 2 On turns on part of your system designated as Part 2 leaving the rest of the system turned off You can select the points that turn on for Part 2 On refer to Set Part 2 Points Cmd 65 on page 23 1 Make sure Part 2 points are normal not faulted If your system has a faulted point you should ...

Страница 22: ...g exit delay you may stop the system from turning on by entering your passcode If you wish you can turn the system Part 2 On with No Delay refer to Section Turn The System On With No Delay on page 24 by pressing No Delay or you may bypass points by pressing Bypass 4 During the last 10 seconds of Exit Delay the Exit Delay tone becomes more urgent warning you not to exit or to turn the system off Th...

Страница 23: ...turned off All and Part indicators are off 2 Press Cmd 6 5 The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode if necessary The keypad indicates which points are available for selections Points that are on steady are selected for Part 2 flashing points are available for selection 4 Enter the Point Number you want to activate or deactivate for Par...

Страница 24: ...f necessary The keypad display lights the Cmd indicator and either the All On or Part On indicator 4 Press No Delay to turn the system on with no delay There is a 10 second window before the panel arms as No Delay 5 To turn the system off enter your passcode Turn The System On With No Exit Tone Use this command to turn the entire system All On Part On or Part 2 On without any exit tones Remember t...

Страница 25: ...d Part On or Press Cmd then press and hold 2 Part 2 On Press Cmd then press and hold 3 Silencing the Exit Delay Tone doubles the Exit Delay period All On Cmd 1 Operation All and Cmd LEDs are on during the Exit Delay period Part On Cmd 2 Operation Part and Cmd LEDs are on during the Exit Delay period Part 2 On Cmd 3 Operation Part and Cmd LEDs are on during the Exit Delay period The Cmd indicator t...

Страница 26: ...doubled Exit Delay time and no exit tone press and hold All On or Part On until the Cmd LED lights after approximately one second The faulted point s LED indicator remains on Press All On or Part On again If the Cmd indicator flashes enter your passcode The All or Part indicator turns on indicating the system is turning All On or Part On The Exit Delay Time countdown is doubled and begins without ...

Страница 27: ...nts it from monitoring undesired points 1 Ensure the system is turned off All and Part indicators are not illuminated 2 Press BYPASS The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode if necessary 4 Enter the Point Number that you want to bypass followed by the key For example if you want to bypass Point 10 enter 1 0 Repeat this step until all p...

Страница 28: ...MM DD YY HH MM format shown in Figure 12 Figure 12 Date and time format ___ M ___ M ___ H ___ H Month of the year Day of the month Current Year Hour of the day Minute of the hour ___ D ___ D ___ M ___ M ___ Y ___ Y The keypad lights points 1 through 6 each point represents a digit to be entered for the date and points 1 through 4 for the time Figure 13 Date And Time Digit Indication On Keypad 1 2 ...

Страница 29: ... this command Use this command to change your passcode at any time Only use this feature under the direction of your security company Write down your old passcode and the new one before you begin 1 Make sure your system is off All and Part indicators are off 2 Press Cmd 5 5 The keypad flashes the Cmd indicator to prompt you to enter your passcode 3 Enter your current passcode The keypad lights you...

Страница 30: ...e this command to change passcodes for each user in the system This command requires the appropriate authority level to change passcodes Cmd 56 is only for changing passcodes other than the one used to access Cmd 56 For example if User 1 performs Cmd 56 User 1 cannot modify User 1 s own passcode Use Cmd 55 instead 1 Make sure the system is turned off All and Part indicators are off 2 Press Cmd 5 6...

Страница 31: ...want to change followed by the key For example press 2 to change the Passcode for User 2 The point indicator for that particular user number now stays on steady If the user does not exist in the system the keypad emits an error tone 6 Enter a new passcode with the same number of digits as the old passcode If the error tone sounds try a different new passcode Enter the new passcode again for verifi...

Страница 32: ...illed in by your security company Authority Level 1 includes these commands _________________________________________________ Authority Level 2 includes these commands _________________________________________________ Authority Level 3 includes these commands _________________________________________________ Authority Level 4 includes these commands ________________________________________________...

Страница 33: ...r or press Cmd twice to exit Add A Passcode Cmd 56 o I can perform this command o I cannot perform this command Use this command to add new passcodes to the system This command requires the appropriate authority level to add passcodes To add a new passcode to the system you must assign an area s to the new user in addition to using the other Cmd 56 features changing a passcode and changing a passc...

Страница 34: ...s 1 to assign a new passcode 9 Enter the user number followed by the key For example press 4 to create the passcode for User 4 10 Enter a new passcode If the error tone sounds try a different new passcode 11 Enter the new passcode again for verification Press Cmd twice Point indicators 1 to 3 flash 12 Press 2 to assign a passcode authority level to the new user 13 Enter the user number followed by...

Страница 35: ...stem is turned off All and Part indicators are off 2 Press Cmd 5 8 The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode The available user numbers flash Figure 16 Available User Numbers 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 All Cmd Part Status 4 Enter the user number you want to delete For example press 2 to delete User 2 You cannot delete yourse...

Страница 36: ...ime passcodes Once renewed the one time passcode is again able to turn the system off only once 1 Make sure the system is turned off All and Part indicators are off 2 Press Cmd 5 3 The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode The keypad sounds the OK tone 4 Press 0 if you want to renew all one time passcodes or press the number of the user...

Страница 37: ...ype of system trouble Refer to Table 5 Table 5 System Troubles Point Description 1 Weekly Test Due Prompts you to conduct your weekly system test refer to System Test Cmd 41 on page 42 Table 5 System Troubles continued Point Description 2 System Trouble Press 2 to determine the specific trouble refer to View System Trouble Cmd 42 on page 39 3 Remote Program Session Active Security company is curre...

Страница 38: ... cannot perform this command After an alarm has been silenced and cleared from the display you may still review the points that were in alarm 1 Make sure the system is turned off All and Part indicators are off 2 Press Cmd 4 0 Enter passcode if prompted The keypad displays all points that are in alarm memory 3 To clear the alarm memory turn the system on and then off If the point indicator is flas...

Страница 39: ...dition may occur if there is a communications trouble or it is time for the system to be serviced by your security company 1 Make sure the system is turned off All and Part indicators are off 2 Press Cmd 4 2 The keypad may prompt you to enter a valid passcode by flashing the Cmd light 3 Enter your passcode The keypad displays current system trouble events by lighting the point indicators Refer to ...

Страница 40: ...aller Switch Closed On Backup Battery Low 4 Flashing Slow Backup Battery Missing 5 On Bell Supervision Fail On RF Receiver Jammed 6 Flashing Slow RF Receiver Trouble On Data Bus Device Missing Flashing Slow Data Bus Tamper 7 Flashing Fast Data Bus Device Trouble Reset Table 6 System Trouble Events continued Point Description On System Fault Flashing Slow Service Interval 8 Flashing Fast Ground Fau...

Страница 41: ...l and Part indicators are off 2 Press Cmd 4 8 The keypad may prompt you to enter a valid passcode by flashing the Cmd light 3 Enter your passcode The keypad displays all points that are in trouble if any Refer to Table 7 The keypad only displays Points 1 to 16 Table 7 Trouble Points Point Trouble Condition Off No Point Trouble On Wiring Fault Flashing Slow RF Sensor Low Battery Flashing Fast RF Se...

Страница 42: ...em test if a phone line is connected 1 Make sure the system is turned off All and Part indicators are off 2 Press Cmd 4 1 The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 3 Enter your passcode if necessary The system starts the test As each test is underway the corresponding point indicator lights Refer to Table 8 Table 8 System Test Lights Point Testing 1 Bell 2 S...

Страница 43: ...ch test Refer to Table 9 Table 9 System Test Point Status Point Testing Status Flash Slow Testing Segment Underway Flash Fast Testing Segment Failed On Testing Segment Complete 4 When the test is complete the keypad automatically exits this command 5 To stop the test currently in progress and skip to the next test press the key To abort all system tests and return to the normal display press the C...

Страница 44: ...scode if necessary The keypad emits a single tone 4 To test each point trigger the corresponding detection device such as open a door or walk in front of a motion detector until all points are tested When a point is tested the keypad emits a single one second tone and the corresponding point indicator turns on When the tested point is restored the keypad emits a second single one second tone and t...

Страница 45: ...de if necessary The system now resets After the system resets the keypad automatically exits this command Turn Watch On Off Cmd 61 o I can perform this command o I cannot perform this command Use the Watch feature to watch points when the system is off For example parents with small children may want a tone to sound whenever a door or window is opened as a way of monitoring the location of the chi...

Страница 46: ...e ability to watch points when the system is off For example parents with small children may want a tone to sound whenever a door or window is opened as a way of monitoring the whereabouts of the children Use this command to set the type of response your system produces when a watch point is faulted If you wish you may tell your system to display the point s LED indicator and sound a short tone wh...

Страница 47: ...10 Watch Tones Choice Tone 1 No Tone 2 Short Beep 3 Beep Until Key 4 Beep Until Closed 5 If you just want to review not change the current watch tone setting press Cmd to exit this function Table 11 gives a description of each watch tone Table 11 Watch Tone Description Watch Tone Description Off Displays point s but no tone when point s is faulted Short Beep Displays point and sounds a short tone ...

Страница 48: ...tell your system which points to watch You cannot watch 24 hour or fire points Choosing which points to watch depends upon your goals If you have small children you may choose to watch points of entry and exit Each time a watch point is faulted a door or window is opened the keypad responds as programmed For example you may tell your system to produce a short beep when a watch point is faulted 1 M...

Страница 49: ...atch Points 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 All Cmd Part Status 5 Press Cmd to exit this command Extend Auto On Time Cmd 51 o I can perform this command o I cannot perform this command Your security company can program your system to turn on automatically This command allows you to delay the auto on time by one hour during the auto on pre alert time 1 Make sure the system is turned off All ...

Страница 50: ... valid passcode by flashing the Cmd indicator 2 Enter your passcode If your passcode is valid the keypad illuminates the All On indicator and exit delay starts If an area has a faulted point s when you try to turn all areas All On the appropriate point LED illuminates Points 1 to 16 Hold down the All On key for two seconds to force all areas to All On The keypad lights Point Indicators 1 to 4 to i...

Страница 51: ...ssary The keypad turns off all areas at the same time Auto Forward On Off Cmd 82 o I can perform this command o I cannot perform this command This command allows you to turn on or off the auto forward feature as necessary 1 Press Cmd 8 2 The keypad may prompt you to enter a valid passcode by flashing the Cmd indicator 2 Enter your passcode if necessary The keypad sounds the valid entry tone 3 Pres...

Страница 52: ... one short beep waits approximately 3 seconds and then sounds one long beep if the panel is off Press and hold the 5 key for two seconds immediately after the first short arming beep and before the long beep begins arms if it detects a 5 key press from the telephone All On with Delay faulted points are force armed The panel sounds three beeps new armed state and then hangs up If arming from a cell...

Страница 53: ...ompleted the keypad automatically exits this command Security System Limitations Not even the most advanced security system can guarantee protection against burglary fire or environmental threats All security systems are subject to possible compromise or failure to warn for a variety of reasons including but not limited to the following If sirens or horns are placed outside the hearing range of pe...

Страница 54: ... may make you eligible for reduced insurance premiums the system is no substitute for insurance Warning devices cannot compensate you for loss of life or property Fire Safety And Evacuation Residential fire is a leading cause of accidental death Most fire related deaths occur at night when occupants suffocate in their sleep from smoke and toxic gases rather than from burns To help reduce this risk...

Страница 55: ...dy exist 6 As a part of this plan all family members should arrange to meet at a location away from the house such as a neighbor s house so you will know that everyone is accounted for 7 If it is determined that the alarm was accidentally sounded the bell should be silenced the detectors reset and your security company notified immediately that there is no emergency situation Figure 18 Smoke Detec...

Страница 56: ...es and unfinished attics Maintenance and Service Your security system requires very little maintenance however you should test the system weekly to ensure it is working properly A test schedule and maintenance program can be arranged If you notice a change in operation during normal use or testing call for service as soon as possible Do not attempt to repair the control panel keypads or detectors ...

Страница 57: ...rity company for service If the transformer is plugged in check the circuit breaker supplying power to the outlet If the breaker is tripped check the appliances on the circuit for signs of electrical problems Make sure someone has not intentionally turned the breaker off When all is clear reset the breaker Refer to the information box refer to Figure 1 on page 2 for the transformer information and...

Страница 58: ...onditions enabling central station personnel to dispatch the proper authorities Controlled Point Point that reports alarm conditions only when the system is turned on Entry Delay Programmed delay of the system alarm response that allows you to enter the building through the entry door to turn your system off An alarm response begins if you do not turn the system off before the entry delay expires ...

Страница 59: ... Point Type of 24 Hour Point that is always on and cannot be turned off Off Display Display that appears when the system is turned off and no keys are pressed Part On Turn on part of the points in the system Part On points are determined by your security company Part 2 On Turn on part of the points in the system Part 2 On points are determined by you the user Point Detection device or group of dev...

Страница 60: ...D621 Series User s Guide Glossary Bosch Security Systems 8 04 60 Warble Tone Tone that is on for one second then briefly off ...

Страница 61: ...D621 Series User s Guide Notes Bosch Security Systems 8 04 61 Notes ...

Страница 62: ... 2004 Bosch Security Systems For technical support please contact ...

Отзывы: