Servicing and spares
|
37
6 720 ... ... (YYYY/MM)
Product Name
2.5F
Service reminder
When this function is set on the control
system, this service is not displayed.
Possible settings are:
• 0: not active
• 1-72, 1 to 72 months can be set
and after the expiry of this period,
the display shows the a service is
required.
Default is 0
2.7b
3-way valve in the
middle position
After saving the value 1, the 3-way
valve moves to the centre position.
The complete emptying of the water in
the system can be ensured allowing
the removal of the heat exchanger.
After 15 minutes, the value 0 is
restored automatically.
The middle position of 3-way valve is
not displayed.
2.7E
Screed drying
function
This function only provided heat for
screed drying, the appliance does not
function as a central heating boiler, no
other settings are possible:
0: off
1: heating only on the device or
controller setting, i.e. all other heat
requirements are locked.
Default is 0
As long as the screed drying function is
active, the text line shows 7E
2.9F
CH Pump delay time The CH pump delay time begins at the
end of heat demand.
Possible settings are:
• 0 to 60: Follow-up time in minutes
(1-minute increments)
• 24H: follow-up time 24 hours.
Default setting is 3 minutes.
2.9L
Hot water cylinder
thermal disinfection
This feature enables the storage
cylinder to be heated to 70 °C.
Possible settings are:
• 0: Thermal disinfection is not active
• 1: Thermal disinfection active
Default setting is 0 (not active).
Thermal disinfection is not displayed.
The water is maintained at 70 °C for
35 minutes, to complete the thermal
disinfection.
Service function
Possible settings
Table 20 Menu 2
2.CE
Circulation pump
starts
Active only with activated circulation
pump (service function 2.CL).
This service feature allows you to set
how often the circulation pump is
running in an hour for 3 minutes.
Possible settings are:
1: 3 minutes on, 57 minutes off.
2: 3 minutes on, 27 minutes off.
3: 3 minutes on, 17 minutes off.
4. 3 minutes on, 12 minutes off.
5: 3 minutes on, 9 minutes off.
6: 3 minutes on, 7 minutes off.
7: Permanently on
Default setting is 2
2.CL
Circulation pump
This service function a connected
circulation pump is activated. Possible
settings are:
• 0: not active circulation pump
• 1: Circulation pump active
Default setting is 0
Service function
Possible settings
Table 20 Menu 2