Servicing and spares
|
35
6 720 ... ... (YYYY/MM)
Product Name
10.2.2 Selecting the Information menu
The Information Menu is a “read only”menu. Information about the boiler
is displayed here, some of the values are updated in real time to give the
current status of the boiler.
The menu backlight turns off after 30 seconds of inactivity and all menus
time-out after two minutes of inactivity and the display returns to the
normal operation display.
Double up or down arrows indicate that the menu can only be scrolled up
or down, an up and down arrow combination indicates position in the
menu where options can be scrolled either up or down.
To enter Information menu:
▶ Press the
button
▶ Press the
+
or
-
buttons to scroll through the Information menu
10.2.3 Selecting menu 1
To display a service function in this menu:
▶ Press the
button and the
ok
button simultaneously until in the
text line Menu 1 is displayed.
▶ Press the
ok
button to confirm your selection.
▶ Press the
+
or
-
buttons to scroll through the menu area.
10.2.4 Selecting menu 2
To display a service function in this menu:
▶ Press the
button and the
ok
button simultaneously until in the
text line Menu 1 is displayed.
▶ Select menu 2 with the
+
button.
▶ Press the
ok
button to confirm your selection.
▶ Press the
+
or
-
buttons to scroll through the menu area.
Service functions
Comments
i1
Current operating
state
Every operation and mode of the boiler
has a related boiler status code.
The boiler status code is displayed on the
screen as a three figure number.
Refer to Status code table on page 51
i2
Operating code for
the last error
This can be viewed during normal
operation. Displays the last diagnostic
code with boiler status code.
i3
Maximum shared
heating
Setting of service function 2.1A
i4
Maximum shared
power (Hot water)
Setting of service function 2.1b
i7
Flow temperature
The actual control system supply
temperature required
i8
Ionisation current
When the burner is running:
•
2 micro Amp = OK
• < 2 micro Amp = faulty
With burner off:
• < 2 micro Amp = OK
•
2 micro Amp = faulty
i9
Temperature at
temperature flow
sensor
This is the actual temperature from the
main heat exchanger displayed in real
time.
i12
DHW temperature
The hot water set temperature
i13
Temp. at the storage
tank temp. sensor
only with attached hot water tank
i15
Current outside
temperature
Only displayed when an external
temperature sensor system is connected.
i16
Actual system pump
modulation
Display in % of pump modulation (system
boiler only)
i17
Current heating
Display in % of maximum rated heat output
in heating mode
1)
1) During the water heating, values greater that 100% are displayed in menu 1
i18
Current fan speed
Display in revolutions per second (Hz)
i20
Software version
circuit board 1
Firmware version of the main control
board.
i21
Software version
circuit board 2
Firmware version of the fascia control
display board
i22
Code plug number
The last three digits of the code plug
(HCM) are displayed
i23
HCM version
Version of the code plug (HCM) is
displayed
Table 18 Information menu
Service function
Possible settings
1.W1
Weather compensation
0 = off,
1 = on
1.W2
Weather compensation, point A @ -10 °C °C (default 90 °C)
1.W3
Weather compensation, point B @ 20 °C °C (default 20 °C)
1.W4
Weather compensation, Automatic
Winter/Summer switch point
°C
(default 16 °C)
1.W5
System frost protection
0 = off,
1 = on
1.W6
System frost protection temperature
°C (default 5 °C)
1.7d
Open shunt sensor input
0 = None,
1 = at the boiler,
2 = at the module
Table 19 Menu 1
Service function
Possible settings
2.1A
Maximum heat
output
Some gas utilities require a
performance-based basic price.
The heat output can be limited to
between the minimum rated output
and maximum rated output for specific
heating requirements.
Default setting is the maximum rated
output.
▶ Adjust the heat output in kW.
▶ Compare the gas flow rate with the
data tables 5 & 8. In case of any
deviations, correct the setting.
2.1b
Maximum DHW
performance
The heat output can be limited to
between the minimum rated output
and maximum rated output for specific
heating requirements.
Default setting is the maximum DHW
output.
▶ Adjust the heat output in kW.
▶ Compare the gas flow rate with the
data table 5 & 8. In case of any
deviations, correct the setting.
2.1C
Pump head selection The pump speed and modulation
behaviour is controlled by this setting
to always modulate based on the
burner power.
0: Pump modulates depending on
burner power
Setting fixed to always be 0
Table 20 Menu 2