4.
Set the slide‑switch (2) at the base of the device from the participant’s setting (0)’ to the
chairperson’s setting (1)’. See figure in Erase address, page 37.
5.
Reconnect the device to the system cabling. A restart of the system is not necessary.
A total of 25 Discussion Devices can be configured as chairperson’s devices/interruption
microphones.
For example: 22 chairperson’s d 3 interruption microphones = 25 devices in total.
Initialize Discussion Device
When a Discussion Device is powered on for the first time, it has no address and no
association with the Control Unit. To indicate this:
–
the light-ring in the head of the microphone is lit red.
–
the LED indicator above the microphone button is lit amber.
To initialize/address a Discussion Device:
1.
Push the microphone button once.
2.
Wait until all LEDs on the device are off. The device is then correctly initialized.
3.
If the device does not initialize correctly, erase the address as described in Erase address,
page 37, and then push the microphone button to initialize/address the device
Note: The address can also be erased in the web browser interface, by clicking the de-init
button on the seat settings page. For more information, see System settings, page 45 > Seats.
Erase address
1.
Push and immediately release the concealed initialization button (1) at the base of the
Discussion Device:
–
The light-ring in the head of the microphone is lit red.
–
The LED indicator above the microphone button is lit amber.
2.
Initialize the device as described in Initialize Discussion Device, page 37.
0
1
6
1
6
2
Figure 7.4: Base view
1.
Concealed initialization button.
2.
Slide‑switch for configuring.
7.3.2
7.3.3
Digital Discussion System
Configuration | en
37
Bosch Security Systems B.V.
Operation manual
2016.05 | V2.0 |
Содержание CCS 1000 D