Service Manual
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units
| 89
Bosch Thermotechnology Corp.
|
08.2020
Data subject to change
7. Remove the four
À
xing screws of the fan motor. Then remove the fan motor.
Figure 152
9.4.2 Removing the panel plate
1. Stop operation of the air conditioner and turn “OFF” the power breaker.
2. Remove the big handle and water collector (4 screws).
Figure 153
Screws of
Water collector
Screws
of big
handle
3. Remove side and rear panel (17 screws).
Figure 154
Screws of
terminal board
Screws of right
rear panel
Screws of right
rear panel