4.5 For Model: 48K Multi Zone Regular System
BMS500-AAM048-1CSXRA
Figure 6
LIQUID VALVE A
GAS VALVE A
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COOLING
HEATING
T2 Evaporator
temp. sensor
T1 Room
temp. sensor
T3
Condenser
temp. sensor
T4 Ambient
temp. sensor
INDOOR
OUTDOOR
EXV A CAPILLARY A
CHECK VALVE
CAPILLARY TUBE
EXV B CAPILLARY B
LIQUID VALVE B
GAS VALVE B
EXV C CAPILLARY C
LIQUID VALVE C
GAS VALVE C
EXV D CAPILLARY D
LIQUID VALVE D
GAS VALVE D
EXV E CAPILLARY E
LIQUID VALVE E
GAS VALVE E
Compressor
4-WAY VALVE
T5 Discharge
temp. sensor
Accumulator
High pressure
switch
Low pressure
switch
T2B-A Evaporator
temp. sensor outlet
T2B-B
T2B-C
T2B-D
T2B-E
5 Wiring Diagram
Refer to wiring diagram in the installation manual (IOM) or on the unit.