9.1.4 Removing the compressor
1. Follow steps outlined in Section 9.1.2.
2. Remove the electrical control box cover and extract refrigerant from the
refrigerant circuit.
3. Remove the sound insulation material and crankcase heating cable.
4. Remove terminal cover of compressor, and disconnect wires of crankcase
electric heater and compressor from the terminal.
5. Remove the discharge pipe and suction pipe with a burner
Figure 97
6. Remove the hex nuts and washers
À
xing the compressor on bottom plate.
Figure 98
7. Lift the compressor from the base pan assembly.
9.1.5 Removing the reactor
1. Follow steps outlined in Section 9.1.2.
2. Remove connector between IPM and reactor.
Figure 99
3. Remove the screws of reactor (3 screws).
Figure 100
Screws