50
6.4
Checking the ignition point and
dwell angle
6.5
Checking the dwell angle
3.
Connect the clip-on trigger sensor to
the BEA.
4.
Clamp the clip-on trigger sensor over
the loop of your P 100.
5.
Connect the B-cable of the BEA to the
B-jack of your P 100.
6.
Switch on the P 100. The timing light
begins to flash.
7.
Flash the timing light at the photo
diode in the P 100 and set the ignition
point to 10°crankshaft using the ad-
justing wheel of the timing light.
8.
Compare the value on your P 100 with
the value displayed on the BEA.
Nominal value:
10°crankshaft + 0.5°crankshaft
9.
Repeat the test with an ignition point
of 60°crankshaft
Nominal value:
60°cran 0.5°crankshaft
i
Use F3 to change the dwell angle
between %, ms or degrees (°).
1.
Connect the Term.1 connection cable
(green banana plug) to the Term.1
jack of your P 100.
2.
Connect the B-cable of the BEA to the
B-jack of your P 100.
3.
On your P 100, set an engine speed
of 1000 rpm.
Then set the P 100 to a dwell angle
of 50%.
Nominal value: 50% + 0.5%
4.
Repeat the test with a dwell angle
of 20%
Nominal value: 20% + 0.2%
Содержание BEA 150
Страница 91: ...92 12 Overview 12 1 Electrical wiring Siemens analysis chamber 459716 2Ha ...
Страница 94: ...95 12 4 Hosing Siemens analysis chamber X26 X24 X25 X22 X5 LP 223 X19 459716Ht ...
Страница 96: ...97 12 6 Electrical wiring Andros analysis chamber 4597162Ht ...
Страница 99: ...100 12 9 Hosing Andros analysis chamber 459869_03Ht ...
Страница 100: ...101 12 10 Gas circuit diagram Andros analysis chamber ...