Model

30K

36K

MBRS42HPJ1OA

Minimum number of

connectable indoor units

2

2

2

Maximum number of 

connectable indoor units

4

5

5

Minimum capacity of 

connectable indoor units

18KBtu

18KBtu

18KBtu

Maximum capacity of 

connectable indoor units

42KBtu

48KBtu

56KBtu

The  Free  Match  System  adopts  the  cutting-edge  manufacturing  technology  and  takes  global 

acknowledged,  environmental-friendly  R410A  as  refrigerant,  which  is  a  green  product  in  the  21

st

century. Please carefully read this manual before installation and operation. Instructions before reading 

this manual

(1) This unit measures on the base of UL1995.

(2) Free Match System conforms to design standard: ARI 210240-2008.

(3) For  guaranteeing  personal  safety  when  operating  this  system,  please  strictly  follow  the

(5) Switch the main power on 8 hours before starting the unit, helpful for a successful startup.

display of the wired controller in  five seconds and then the indoor unit will stop. In this case, they can 

back to the normal condition by harmonizing their running modes: the cooling mode is compatible with 

the dehumidifying mode and the fan mode can go with any other mode. If the supply power fails when 

the unit  is running, then the  indoor unit will send the “start” signal  to the outdoor  unit three  minutes 

later after power recovery. 

instructions listed in the manual. 

(4) The total capacity of the indoor units which runs at the same time can not exceed that of the

outdoor units; otherwise, the cooling (heating) effect of each indoor unit would be poor. 

(6) It is a normal phenomenon that the indoor unit fan will still run for 20~70 seconds after the

indoor unit receives the “stop” signal so as to make full use of after-heat for the next operation. 

(7) When the running modes of the indoor and outdoor units conflict, it will be indicated on the

(8) Cautions for the Debugging and Maintenance Personnel:

During debugging and maintenance, prior to the startup of the compress make sure the heating belt

of the compressor has been energized for at least eight hours! Once the compressor is started, it must be 

guaranteed that it works continuously for at least 30 minutes, otherwise it would be damaged! 

Содержание Brisa MBRS42HPJ1OA

Страница 1: ...For proper operation please read and keep this manual for future reference If you have lost the Owner s Manual please contact the local agent or visit www borealintl com or send an email to borealsale...

Страница 2: ...e normal condition by harmonizing their running modes the cooling mode is compatible with the dehumidifying mode and the fan mode can go with any other mode If the supply power fails when the unit is...

Страница 3: ...n of such waste separately for special treatment is necessary Exception Clauses Manufacturerwillbearnoresponsibilitieswhenpersonalinjuryorpropertylossiscausedbythefollowingreasons 1 Damagetheproductdu...

Страница 4: ...3 3 Piping Connection 7 4 Installation Instruction 8 4 1 Outline and dimension of the outdoor unit 8 4 2 Installation of the Connection Pipe 9 4 3 Air Purging and Refrigerant Charge 11 4 4 Electric Wi...

Страница 5: ...pes 10 Never short circuit or cancel the pressure switch to prevent unit damage 11 Please firstly connect the wired controller before energization otherwise wired controller can not be used 12 Before...

Страница 6: ...eries 2 We are not responsible of personal injury or equipment damage caused by improper installation and commission unnecessary service and incapable of following the rules and instructions listed in...

Страница 7: ...roduct lineup is provided with capacity range from 30KBtu to 42KBtu which can be widely used in boarding house and working area and especially applicable to the place with variable load change Our com...

Страница 8: ...drive up to five indoor units which can be cassette type duct type wall mounted or floor ceiling type The outdoor unit will run as long as any one indoor unit receives the running command and all indo...

Страница 9: ...before outgoing 2 The parameters below are tested under rated working condition If there is any change to them please refer to the nameplate 3 The parameters of heating capacity of indoor unit for hea...

Страница 10: ...orrosive gas or exhaust gas 4 Leave some space for heat exchanging and servicing so as to guarantee unit normal operation 5 Keep the indoor and outdoor units close to each other as much units close to...

Страница 11: ...oor Unit and Outdoor Unit ft Liquid Gas 30K 1 4 3 8 229 6 When the outdoor unit is above maximum height difference between indoor and outdoor units is up to 49 2ft When the indoor unit is above maximu...

Страница 12: ...ee match series 8 4 Installation Instruction 4 1 Outline and dimension of the outdoor unit MBRS42HPJ1OA Outline dimension and Mounting holes Fig 5 40 42 1 2 24 5 6 17 1 3 14 1 4 15 3 4 43 3 7 Unit inc...

Страница 13: ...never pull any joints of the indoor unit by force otherwise the capillary pipe or other pipe may crack which then would result in leakage 2 The refrigerant pipe should be supported by brackets that i...

Страница 14: ...nd plastic tape in order to prevent condensation and water leakage 2 The joints of the indoor unit should be wrapped with the insulating material and no gap is allowed on the joint of the indoor unit...

Страница 15: ...rging 1 The refrigerant has been charged into the outdoor unit before shipment while additional refrigerant still need be charged into the refrigerant pipe during the field installation 2 Check if the...

Страница 16: ...ot pull the power cord by force 4 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 5 The diameter of the power cord sh...

Страница 17: ...nnect well according to the instruction 3 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 4 The installation location...

Страница 18: ...test It may cause insufficient cooling heating capacity Is the unit get proper thermal insulation It may causecondensation and dripping Does the unit drain well It may causecondensation and dripping I...

Страница 19: ...blown out again NOTICE If problem can not be solved after checking the above items please contact service center and show phenomena and models Following circumstance are not malfunction Table 11 Malfu...

Страница 20: ...hat of outdoor unit indoor fault indicator will flash and conflict will be shown on the wired controller after 5 minutes Indoor unit stops to run and meanwhile change outdoor operating mode as the sam...

Страница 21: ...h 3 times Outdoor ambient sensor malfunction Flash 6 times Outdoor tube sensor malfunction Flash 5 times Exhaust sensor malfunction Flash 7 times Attain the temperature of switch on Flash 8 times Freq...

Страница 22: ...remote wireless controller has been replaced 4 Check if the filter screen has been set soundly 5 After long period of shutdown open the main power switch 8 hours before re operating the unit so as to...

Страница 23: ...agency designated by us Warranty should meet the following requirements 1 First run of the unit should be operated by professional personnel from appointed service center 2 Only our manufactured acces...

Страница 24: ...Boreal International a Watsco Inc subsidiary borealsales borealintl com www borealintl com 10300 NW 19th St 105 Doral FL 33172 786 621 8250 66129935471...