Installation
www.bora.com
PKAS3/PKAS3AB
5
3
2
1
4
9
21
33
52
Fig. 4.42
Stripping lengths and installation position of the
PKAS3/PKAS3AB connection cable – Home In
5
3
2
1
4
9
16,5
25,5
37
Fig. 4.43
Stripping lengths and installation position of the
PKAS3/PKAS3AB connection cable – Home Out
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
[5]
Cable feed snap-out element
X
X
Please adhere to the maximum stripping length of the
individual wires of 9 mm on the stripped wire end [1].
X
X
Please adhere to the maximum stripping length of the outer
sheath of 21 mm (Home In) and 16.5 mm (Home Out) on the
insulated wire [2].
Installing the external switch device
Depending on the type of switch device, connect the connection
cables to either the Home In or the Home Out connection
clamp.
X
X
Adhere to the connection diagram when connecting Home In
and Home Out.
Home
In
Home
Out
X 311.1 X 311.2
X 312.1 X 312.2
Fig. 4.44
Connection diagram for PKA3/PKA3AB external
switch contact
Home
In
Home
Out
X 312.1 X 312.2
X 311.1
X 311.2
Fig. 4.45
Connection diagram for PKAS3/PKAS3AB external
switch contact
X
X
Connect the cable for the relevant contact to the switch
contact clamp in accordance with the connection diagram.
X
O
In order to connect the Home In interface, the installed bridge
must be removed.
i
The Home In contact must be bridged if this is not used
(bridged on delivery).
i
For connections to the Home In connection clamp, no
ferrules may be used.
2
3
1
Fig. 4.46
Cable tie Home-In interface PKAS3/PKAS3AB
[1]
Cable tie
[2]
Insulated wire
[3]
Home-In interface PKAS3/PKAS3AB