EN
21
Gas installation
www.bora.com
6.5 Handover to user
Once installation is done:
X
X
Explain the important functions to the user.
X
X
Explain all safety-relevant aspects of operation and
handling to the user.
X
X
Provide the user with the accessories and operating
and installation instructions to be kept in a safe place.
6.6 Nozzle table
INFO
Use only stamped and approved nozzles.
Gas type
LPG (liquid gas)
NG (natural gas)
Gas burner
(position)
Peak
pressure
(mbar)
Nozzle
diameter
1/100mm
Heat output
g/h l/h
Heat output (W)
min. max.
Energy
consumption**
G30 butane
LPG
Back
50
72 M
204
800
2800
G31 propane
LPG
Back
50
72 M
200
800
2800
G20 natural gas
NG
Back
20
117 Y
267
800
2900
69 %
G30 butane
LPG
Front
50
46 M
73
450
1000
G31 propane
LPG
Front
50
46 M
71
450
1000
G20 natural gas
NG
Front
20
75 X
95
450
1000
Tab. 6.4: Standard nozzle table
** In accordance with Commission Regulation (EU)
No 66/2014 implementing Directive 2009/125/EC,
the power (energy consumption) has been tested and
calculated using G20 pursuant to EN 30-2-1.
Gas type LPG
(liquid gas) NG
(natural gas)
Peak
pressure
(kPa)
Gas burner
(position)
Nozzle diameter
1/100mm
Heat output
(MJ/n)
G30
butane
LPG
2.75
Back
91
10.4
G31
propane
LPG
2.75
Back
91
10.4
G20
natural gas
NG
01:00
Back
155
12.0
G30
butane
LPG
2.75
Front
53
3.6
G31
propane
LPG
2.75
Front
53
3.6
G20
natural gas
NG
01:00
Front
90
4.1
Tab. 6.5: Australia/New Zealand nozzle table