4. OPERATING FAILURES
Sensor failures
- E40: 1 or 2 (out of 3) core probe sensors are cut.
- E41: 1 or 2 (out of 3) core probe sensors are short-circuited.
- E61: Short-circuited ambient probe.
- E62: Cut ambient probe.
- E63: Core probe missing or cut.
- E64: Short-circuited core probe.
- E69: Steam boiler at +110°C.
- E70: Short circuited boiler sensor.
- E71: Cut boiler sensor.
Other failures
- E42: Maximum temperature within the electronic facia exceeded.
- E43: Saturated steam inlet activated more than 30 seconds in steam mode.
(Choked condenser nozzle, condenser supplied with hot water or insufficient flow-rate).
- E45: Inoperative boiler drainage.
- E46: Defective communication bus I2C.
- E47: Saturated USB flash drive (in case of option).
- E51: Set ambient temperature at 0.
- E52: Set duration or core temperature at 0.
- E53: Ventilation: failure to operate.
- E67: Activated gas safety inlet.
- E68: Capacity temperature at + 290°C.