Page 27
3BE390692NM – 10/10
BONNET GRANDE CUISINE
Registered Office:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
11.4 06111 MAINTENANCE: Technical assistance
Value read by the ambient
sensor
3 values read for the 3 core
probe sensors.
Value read by the steam
generator sensor
(Gas Précisio)
State of the different inlets :
0 = non-activated, 1 =
activated.
T°:
E1:
044°
E2 :
040°
E2-b :
129°
E2-c :
128°
E4
DOOR SENSOR:
0
/1
E5
CONDENSER INLET:
0
/1
E6
SAFETY INLET:
0
/1
E7
LEVEL SENSOR INLET:
E8
INLET 0 VALVE IN :
0
/1
E9
INLET 0 OURA :
0
/1
TECHNICAL ASSISTANCE
0622
RETURN
0
/1
OUTLETS
E3 :
92°
E5: Condenser inlet
If 0 clicson opened (temperature < 60°)
If 1 clicson closed (temperature > 60°)
E4: Door sensor
If 0 door opened
If 1 door closed
E6: Gas safety inlet
If 0 Burner pilot flame burning
If 1 Burner pilot flame out (defective ignition)
E7: Steam generator water level sensor
If 0 generator sensor uncovered
If 1 generator sensor immersed
E8: Inlet of valve IN (lower valve – air inlet)
If 0 valve opened
If 1 valve closed
E9: OURA valve inlet (Upper valve – discharge of excess steam)
If 0 valve opened
If 1 valve closed
Notes E8 and E9: The operation of the corresponding outlet in the outlet menu enables the operation of
corresponding inlets with display of 0 and 1 to be checked.