4.2.2.2. ASB
3534I3
I
NTERFACE
B
OARD
Figure 4-2: ASB 3534I3 Interface Board Features
3534I3
I
NTERFACE
B
OARD
J
UMPER
S
ET
-
UP
The 3534I3 interface card isolates the front panel from the drive system
voltage, and provides an output for remote monitoring of Ready and
Active signals. Jumpers select the contact of each opto FET relay device.
J1:
Selects N.O. or N.C. contact for the Ride-Thru Ready (RTR) signal.
With J1 in the “N.O.” position the contact will be made while the module
is “READY”.
J2:
Selects N.O. or N.C. contact for the Ride-Thru Active (RTA) signal.
With J2 in the “N.O.” position the contact will be made while the module
is “ACTIVE”.
J3
: Selects N.O. or N.C. contact for the disable (DIS) signal. With J3 in
the “N.O.” position the boost module will be disabled if there is 15-24VDC
on the disable input terminals.
TB4
: The TB4 connector provides a field connection point for Disable,
Ready and Active signals. Signals are isolated up to 3000V.
Ready
– available on TB4- 3 (J1 post) and -4 (common)
350VDC,120mA max
Active - available on TB4-1 (J2 post) and -2 (common)
350VDC, 120mA max
Disable - Input on TB4 terminal 5 (neg DC) and terminal 6 (pos DC)
15-28VDC, (20mA at 28VDC)
4.2.3. R
EMOTE OR
C
ABINET
D
OOR
S
YSTEM
S
TATUS
D
ISPLAY AND
T
EST
M
ODULE
The Ride-Thru Diagnostic Display Panel provides visual indication of the
Ride-
Thru module’s operating status..
The monitored functions include
POWER
,
RIDE-THRU
ACTIVE,
RIDE-
THRU
READY,
and
OVERTEMP
. In addition, this panel provides the system
J3
Disa
ble
J2
RTA
J1
RTR
TB4
TB5
Содержание Legacy M3534R-RY
Страница 6: ...M3534R 40 85A vi This page intentionally left blank ...
Страница 22: ...M3534R 40 85A 16 This page intentionally left blank ...
Страница 42: ...M3534R 40 85A 36 Figure 6 2 M3534R 50kW A9 Chassis Dimensional Outline Dwg 120220 Rev 20120626 ...
Страница 46: ...M3534R 40 85A 40 This page intentionally left blank ...
Страница 54: ...M3534R 40 85A 48 NOTES ...
Страница 55: ......