Warning!
Safety
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
The safety instructions and information on use in this documentation must be complied with strictly.
Read this documentation before installing and commissioning the frequency inverter.
Non-compliance with the precaution described may result in death, serious injury or material
damage.
Only qualified personnel trained in installation, commissioning and operation of frequency inverters
may carry out work on the frequency inverter and system.
The electrical installation must be carried out by qualified electricians according to the general and
regional safety and installation directives
Persons who are not familiar with the operation of the frequency inverter and children must not have
access to the device.
Commissioning and start of operation is not allowed until it has been verified that the machine meets
the requirements of the EC Machinery Directive 2006/42/EC and EN 60204.
Comply with the standards for work on equipment of heavy current installations such as EN 50178
and also with national accident prevention regulations and directives for electrical and mechanical
equipment erection.
Before commissioning and the start of the operation fix all covers, assemble all components of the
standard equipment and check the terminals.
No connection work may be performed, while the power supply is switched on.
High voltage may apply at terminals, even if the motor comes to a standstill.
Do not touch terminals before capacitors have discharged.
Do not touch the heat sink during operation as there is a risk of skin burn due to high temperature.
Do not remove covers during operation.
Do not touch electronic components or contacts.
Do not operate damaged or destroyed components.
Repairs may only be carried out by the manufacturer or persons who are authorized by the manufac-
turer.
Repairs must be carried out by qualified electrotechnical experts.
Do not modify the frequency inverter in any way not explained in this documentation.
The frequency inverter may be connected to power supply every 60 s. This must be considered when
operating a mains contactor in jog operation mode.
After a failure and restoration of the power supply, the motor may start unexpectedly. If personnel is
endangered, a restart of the motor must be prevented by means of external circuitry.
Do not connect an inappropriate voltage supply.
Keep the manual accessible to the operators.
,
,
,