Parameter values can be stored in four different data sets.
If a data set is selected, the entered data is only stored in the selected data set. The other data sets
contain standard values. If no data set is selected the entered data is stored in all four data sets.
The data sets can be switched-over via control terminals (refer to section “Functions of control
terminals”). This enables the setting of different operating points of the drive or settings for different
motors.
P 370
Data set
ENT
Data set
Example 2: Set the motor rated voltage P370 in data set 2.
When setup is carried out the entered and measured motor data is stored in the selected data set.
P 3701
Hold
+
P 3702
ENT
ENT
4002 U
Value of P370 in data set 2
Example 1: Carry out auto-tuning and enter motor data in data set 1.
Display actual values
Parameter
P211
Display
30 A
400 v
P212
R.m.s Current [A]
Output Voltage [V]
Active Power [kW]
Actual Speed [min ]
-1
Actual Frequency [Hz]
Current Error
Warnings
Last Error
P213
P240
P241
P259
P269
P310
R.m.s. output current of the frequency inverter (motor current).
Output voltage of the frequency inverter.
Power of the motor at the current operating point.
Motor speed.
Output frequency of the inverter (actual frequency of the motor).
The cause of error switch-off.
F0102
Warning because of a critical condition.
The last error.
11
1375
50 Hz
A0001
F0102
13
RS485, Modbus or VABus:
RS232, Modbus or VABus:
Profibus-DP:
CANopen or System bus:
Parameter copy
Optional communication modules
Communication interface X21 with RJ45 connection
For serial RS485 communication via VABus or Modbus protocol.
BONFIGLIOLI Vectron provides an interface adaptor for the USB connection of a PC. This enables
parametrization and monitoring via the PC software VPlus.
Reset to factory setting
CM-485
CM-232
CM-PDPV1
CM-CAN
Parameter values can be stored on a standard memory card and transferred from one inverter to
another inverter.
Further information
Detailled operating instructions can be downloaded from the website of BONFIGLIOLI.
Select P34 in menu item
. Set P34 to 4444. This resets the parameter settings to the default
values.
Para
Key lock
Select P27 in menu item
and set a password. Then parameter values in menu item
and
the motorpoti function are password-protected. Ten minutes after a correct password entry the
password inquiry is displayed again.
Para
Para
Data set
Setup
ENT
DSet 0
ENT
DSet 1
DSet 4
...
GB
CM