Modbus Agile
75
02/2011
Parameter List
12 Parameter List
The parameter is available in the four data sets.
12.1 Actual Values ("Actual" Menu)
Actual Value Parameters
No.
Description
Units
Value Range
Chapter
RS485/RS232
11
VABus SST-Error-Register
-
0 ... 15
7.3.9
Actual Frequency Inverter Values
249
Active Data Set
-
0 … 4
10
260
Actual Error
-
0 ... 0xFFFF
13.3
270
Warnings
-
0 ... 0xFFFF
13.1
274
Application Warnings
-
0 ... 0xFFFF
13.2
282
Reference Bus Frequency
Hz
-999,99 … 999,99
11
283
Reference Ramp Frequency
Hz
-999,99 … 999,99
11
Bus Control
411
Status Word
-
0 ... 0xFFFF
10
12.2 Parameters ("Para" Menu)
Parameter
No.
Description
Units
Value Range
Chapter
Bus Control
392 state-transition 5
-
Selection
10.4
RS485/RS232
395 Protocol (CM / X21)
-
Selection
5.4
Bus Control
410 Control Word
-
0 … 0xFFFF
10
412 Local/Remote
-
Selection
10
414 Data Set Selection
-
0 … 4
10
Fixed Frequency Values
484 Reference Frequency RAM
Hz
-999,99 … 999,99
10
Fixed Percentage Values
524 Reference Percentage RAM
%
-300,00 ... 300,00
10
Modbus (RTU/ASCII)
1375 Modbus Parity
-
Selection
6
1376 Modbus Address
-
1 … 247
6
1503 Modbus Mode
-
Selection
6
1504 Modbus Baud rate
Baud
Selection
6
1505 Modbus Watchdog Timer
s
0 … 1000
6
13 Annex
13.1 Warning Messages
The warning messages are given via parameter
Warnings
270, bit-coded according to the following
scheme.
Parameter
Warnings
269 shows the warnings in clear text on the operator panel and the PC software
tool VPlus.
Use Parameter
Warnings
270 to access the warning codes via Modbus.
Warning Messages
Bit-No. Warning Code Description
0
0x0001
Warning Ixt
1) 2)
1
0x0002
Warning Short Time Ixt
1)
2
0x0004
Warning Long Time Ixt
2)
3
0x0008
Warning Heat Sink Temperature Tk
4
0x0010
Warning Inside Temperature Ti
5
0x0020
Warning I-Limit
6
0x0040
Warning Init
7
0x0080
Warning Motor Temperature
8
0x0100
Warning Mains Phase Failure
9
0x0200
Warning Motor Protective Switch
10
0x0400
Warning Fmax
11
0x0800
Warning Analog Input MFI1A
12
0x1000
Warning Analog Input MFI2A
13
0x2000
Warning Systembus Slave in Fault
14
0x4000
Warning Udc
15
0x8000
Warning Application
1) 2)
: Bit 0 "Warning Ixt" is set,
−
if Bit 1 "Warning Short Term Ixt" or
−
if Bit 2 "Warning Long Term Ixt" is set.
In Parameter
Warnings
270 several warnings can be set at the same time.
Example:
Message
Warning Code
Comment
Warning Ixt
0x0001
Set on Short Term or Long Term Ixt.
Short Term Ixt
0x0002
Warning Limit Heat Sink Tem-
perature
0x0008
Warning Limit Motor Tempera-
ture
0x0080
Sum
0x008B
Содержание Agile
Страница 1: ...Agile Modbus Communication manual Frequency inverter 230V 400V ...
Страница 2: ......
Страница 5: ...Modbus Agile 5 02 2011 13 2 Warning Messages Application 76 13 3 Error Messages 76 INDEX 77 ...
Страница 44: ...Modbus Agile 02 2011 44 Handling of Data Sets Cyclic Writing ...
Страница 69: ...Modbus Agile 69 02 2011 10 2 1 Statemachine diagram ...
Страница 78: ......
Страница 79: ......