![Bomag BW 900-2 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/bomag/bw-900-2/bw-900-2_operating-instructions-manual_2785499065.webp)
As required
BOMAG
65
BW 900-2
As r equi red
5.25 Water sprinkler system,
maintenance in the event of
frost
!
Caution
In the event of frost the water sprinkler system
must be drained or filled with an anti-freeze
mixture respectively.
l
Drain all water off.
l
Switch the water sprinkler system on and let all
remaining water run out.
l
Fill the water tank with approx. 5 l of anti-
freeze mixture (water and anti-freeze agent,
e.g. glycol).
l
Run the sprinkler system, until the anti-freeze
mixture starts to run out from the sprinkler
tubes.
5.26 Tightening torques for
screws with metric unified
thread
Fig. 101
* Strength classes for screws with untreated, non-
lubricated surface. The quality designation of the
screws is stamped on the screw heads.
8.8 = 8G
10.9 = 10K
12.9 = 12K
The values result in a 90%ige utilization of the
screws yield point, at a coefficient of friction of tot.
= 0,14.
The compliance with the specified tightening tor-
ques is checked with torque wrenches.
The specified tightening torques do not apply
when using a MoS
2
lubricant.
i
Note
Self locking nuts must always be replaced after
they have been unscrewed.
Содержание BW 900-2
Страница 2: ......
Страница 7: ...BOMAG 7 BW 900 2 1 Technical Data...
Страница 10: ...Technical Data BOMAG 10 BW 900 2...
Страница 11: ...BOMAG 11 BW 900 2 2 Safety regulations...
Страница 18: ...Safety regulations BOMAG 18 BW 900 2...
Страница 19: ...BOMAG 19 BW 900 2 3 Indicators and Controls...
Страница 20: ...Indicators and Controls BOMAG 20 BW 900 2 Fig 5...
Страница 27: ...Indicators and Controls BOMAG 27 BW 900 2 Fig 24 No 18 Water level gauge...
Страница 28: ...Indicators and Controls BOMAG 28 BW 900 2...
Страница 29: ...BOMAG 29 BW 900 2 4 Operation...
Страница 41: ...BOMAG 41 BW 900 2 5 Maintenance...
Страница 67: ...BOMAG 67 BW 900 2 6 Trouble shooting...
Страница 71: ......
Страница 72: ......