Every 10 operating hours
BOMAG
48
BW 900-2
5.8
Checking the hydraulic oil
level
Fig. 61
l
Clean the area around the fuel filler neck.
l
Remove the filler cap.
l
Check the hydraulic oil level on the dipstick.
The oil level must be between the 'MIN' and
'Max' marks.
l
If the oil is below this level fill in hydraulic oil.
For quality and quantity of oil refer to the table
of "fuels and lubricants".
i
Note
If, during the daily inspection of the oil level the hy-
draulic oil level is found to have dropped, check all
lines, hoses and components for leaks.
5.9
Checking the hydraulic oil
filter element
Fig. 62
l
Check the hydraulic oil filter contamination in-
dicator at operating temperature and at maxi-
mum engine speed.
l
I)f the optical display (Fig. 62) shows red, the
hydraulic oil filter element must be changed.
i
Note
After changing the dirty filter the optical display ap-
pears green.
Содержание BW 900-2
Страница 2: ......
Страница 7: ...BOMAG 7 BW 900 2 1 Technical Data...
Страница 10: ...Technical Data BOMAG 10 BW 900 2...
Страница 11: ...BOMAG 11 BW 900 2 2 Safety regulations...
Страница 18: ...Safety regulations BOMAG 18 BW 900 2...
Страница 19: ...BOMAG 19 BW 900 2 3 Indicators and Controls...
Страница 20: ...Indicators and Controls BOMAG 20 BW 900 2 Fig 5...
Страница 27: ...Indicators and Controls BOMAG 27 BW 900 2 Fig 24 No 18 Water level gauge...
Страница 28: ...Indicators and Controls BOMAG 28 BW 900 2...
Страница 29: ...BOMAG 29 BW 900 2 4 Operation...
Страница 41: ...BOMAG 41 BW 900 2 5 Maintenance...
Страница 67: ...BOMAG 67 BW 900 2 6 Trouble shooting...
Страница 71: ......
Страница 72: ......