background image

 

 

 

 

2 Series HD SDI+IP  

Dual Output USB PTZ Camera 

 

USER MANUAL 

VERSION: VCC-2HD

-

M-05022020 

 

 

 

 

 

VCC-M2H5BI-4FN1 

VCC-M2H10BI-4FN1 

 

 

 

 

© 2020 Bolin Technology 

 

 

 

Содержание 2 Series

Страница 1: ...1 2 Series HD SDI IP Dual Output USB PTZ Camera USER MANUAL VERSION VCC 2HD M 05022020 VCC M2H5BI 4FN1 VCC M2H10BI 4FN1 2020 Bolin Technology ...

Страница 2: ...NECTION 19 HOW TO MAKE THE CONNECTION WITH BOLIN PRODUCTS 21 VISCA OVER IP CONTROL 21 VISCA OVER IP NETWORK CONFIGURATION 21 DIP SWITCH SETTINGS 22 ADJUSTING AND SETTING WITH MENUS 25 EXPOSURE MENU 26 WHITE BALANCE MENU 27 PICTURE MENU 28 PAN TILT ZOOM MENU 28 SYSTEMMENU 29 UPGRADING MCU FIRMWARE 30 OPERATION USING THE INFRARED REMOTE CONTROLLER 30 PAN TILT AND ZOOM OPERATION 30 OPERATING MULTIPLE...

Страница 3: ...OLIO LICENSE FOR THE PERSONAL AND NON COMMERCIAL USE OF A CONSUMER TO I ENCODE VIDEO IN COMPLIANCE WITH THE AVC STANDARD AVC VIDEO AND OR II DECODE AVC VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NON COMMERCIAL ACTIVITY AND OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC VIDEO NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION MAY BE...

Страница 4: ... informationabout the use of product Safety Information WARNING Installation and removal of the unit and its accessories must be carried out by qualified personnel You must read all of the Safety Instructions supplied with your equipment before installation andoperation Warnings If the product does not work properly please contact your dealer Never attempt to disassemble the camera yourself We wil...

Страница 5: ...ency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This product complies with Part 15 of the FCC Rules Operation is subject to the foll...

Страница 6: ...6 WHAT S IN THE BOX Note The camera color may be in white or black per the item that is purchased Accessories Optional ...

Страница 7: ...s Speed up to 150 degrees sec Standard mounting and ceiling mounting with E Flip function Control supports RS 232 control RS 422 485 control VISCA over IP IP Onvif UVC IR Remote Controller Presets store camera directions and image parameters Up to 6 presets on remote controller or 128 presets via protocol programming Image parameter setting restore with presets and quick access operation IP Protoc...

Страница 8: ...re upgrade Used for audio input output USB port to 3 5mm audio jack adapter included 6 RS232 RS422 Control Port RJ45 RJ45 to RS422 adapter cable is provided RS232 connection refers to user guide 7 USB Connector TYPE B USB2 0 video output 8 Lens This is a 5X 10X 20X magnification optical zoom lens 9 IR Remote Controller Sensors These are sensors to receive commands from infrared remote controller 1...

Страница 9: ... right orientation setting 6 ZOOM FOCUS Far Near 7 Auto Manual Focus 8 Back Light 9 Video Format Switching You can change the video format by keep pressing the button When video format is changed the camera would restart and the screen turns black for few seconds 10 MENU On screen menu display ON OFF 11 Audio Switch You can turn the Mic built in the camera Off ON by pressing the button once 12 Fas...

Страница 10: ...dget to power the camera or some features may not function properly Cable Requirements Network Cable 10 100 Mbps Ethernet CAT 5 5E 6 UTP cables are applicable to the ANSI EIA TIA 568A B and ISO D Eight wires in the network cable need to be inserted in parallel into the top of the cable connector The cable connector needs to be crimped in position When the cable connector is in position ensure that...

Страница 11: ...output 1 Connect the camera to the network using Cat5 Cat6 network cable 2 You need to have a web browser or VMS client software ready for IP video streaming 3 PELCO address and Baud Rate setting on the camera must be as same as the setting on camera IP WEB interface 4 To obtain IP video and configure IP video please refer to Network Camera User Manual Part Two USB Video Signal This camera support...

Страница 12: ...evices to use 5 Check the box show more options Select Caching to 500ms 6 Interface of the setting page and terminology of the setting items may vary according to the video client software you are using 7 Click Play or Apply the selections and the video will be displayed on the screen The camera is compatible with USB2 0 port The camera USB port will output at the lower resolution while connecting...

Страница 13: ...0 USB2 0 resolution with frame rate are available as following list HDMI FORMAT USB2 0 Resolution Frame Rate 1080P50 1080P25 720P50 1920x1080 10P 1280x720 25P 10P 1024x768 960x540 850x480 800x600 768x448 720x576 720x540 720x480 720x404 640x480 640x360 50P 25P 10P 352x288 ...

Страница 14: ...C UA35IO to connect audio source Note The USB port is only used for Audio physical input and output signal connection The audio signal can be used for IP video streaming USB video streaming HDMI SDI A microphone can be connected to the Audio IN port which feeds audio into the camera It does not support power supply to microphone A speaker can be connected to the Audio OUT port which will output an...

Страница 15: ...O P D 4 IP Control See Network Camera User Manual Use the Infrared Remote Controller To operate the camera from a short distance For IR remote control details refer to Operation Using the Infrared Remote Controller Use RS 232 VISCA You can use RS 232 port to connect to optional controllers such as joystick control keyboard control PC station to operate the camera To perform pan tilt and zoom opera...

Страница 16: ... controller set camera Dip Switch address to 0 5 Reboot the camera by turning it Off On after the Bottom Dip Switch has been set up correctly 6 Camera supports Daisy Chain connection up to 7 cameras 7 The controller must be VISCA compatible 8 You must use CAT5 6 network cable to make RS232 connection by following the pin definition below Do not use regular premade network cable nor the cable adapt...

Страница 17: ...ecific camera address that you want to control the camera for on Bottom Dip Switch 4 If you want to have the camera address to be automatically assigned by VISCA controller set camera Dip Switch address to 0 5 Reboot the camera by turning it Off On after the Bottom Dip Switch has been set up correctly 6 Use the RJ45 to RS422 control cable The controller must be VISCA compatible 7 Camera supports D...

Страница 18: ... make RS422 connection for your control device 12 Or you can use CAT5 6 T 568B Standard Ethernet cable direct connect between the camera and the controller to make RS422 connection by following the pin definition below 13 How to make RS422 Daisy Chain multiple camera connection with RS422 standard serial port controller ...

Страница 19: ...by turning it Off On after the Bottom Dip Switch has been set up correctly Use PELCO P D compatible keyboard Use preset 95 on the keyboard to bring up exit camera OSD menu Use joystick and Button OPEN or CLOSE to navigate OSD menu To operate keyboard please refer to the user manual of the keyboard you are using PELCO RS485 Connection Use extension cables included RJ45 to RS422 Phoenix connecter ad...

Страница 20: ...aisy chain connection for using multiple cameras For control details refer to Operating Instructions of control keyboard station software You need to match the communication speed Baud Rate between the camera and the joystick controller You cannot use the RS 232 connections while you are using the RS422 485 connection Operating Multiple Cameras Using RS 232 422 485 Using RS 232 VISCA you can conne...

Страница 21: ...f VISCA over IP are followings Interface RJ 45 10 100M Interface protocol IPv4 Transport protocol UDP IP address 192 168 0 13 By default Port 52381 VISCA over IP Network Configuration Re assign the camera The default information of the IP camera is following Static IP 192 168 0 13 Subnet mask 255 255 255 0 Gateway 192 168 0 1 VISCA over IP control port 52381 The camera IP address needs to be assig...

Страница 22: ...network Note How to re assign the IP address to the camera please refer to user manual Part Two IP Camera user guide DIP SWITCH SETTINGS The bottom dip switch is for setting the camera configuration for following items 1 Camera ID Address for RS 485 PELCO protocol 2 Video output Video color space 3 RS 232 RS 422 485 selection 4 RS 232 RS 422 485 baud rate 5 Video resolutions selection 6 IR remote ...

Страница 23: ...lay on HDMI device set the Dip switch B4 to OFF When using HDMI to DVI convertor to have DVI video output set the Dip switch B4 to ON 3 RS 232 RS 422 Setting B6 RS 232 RS 422 OFF RS 232 ON RS 422 4 RS 232 RS 422 Baud Rate Setting B7 B8 RS 232 RS 422 Baud Rate Setting OFF OFF 2400 bps ON OFF 4800 bps OFF ON 9600 bps Default ON ON 38400 bps B4 Color Space Setting OFF YUV ON RGB ...

Страница 24: ...Setting B1 B2 B3 B4 Video Resolution OFF OFF OFF OFF 1080i59 94 OFF OFF OFF ON 1080p29 97 OFF OFF ON OFF 720p59 94 OFF OFF ON ON 1080p59 94 OFF ON OFF OFF Empty OFF ON OFF ON 1080i60 OFF ON ON OFF 1080p30 OFF ON ON ON 1080p60 ON OFF OFF OFF 1080i50 ON OFF OFF ON 1080p25 ON OFF ON OFF 720p50 ON OFF ON ON 1080p50 ON ON OFF OFF Empty ON ON OFF ON Empty ON ON ON ON 720p60 ...

Страница 25: ...ursor The cursor moves up or down by pressing the button on the infrared remote controller 2 MenuItems To display a setting menu select one using the button on the infrared remote controller and press the HOME button on the infrared remote controller Setting Menus The setting menu selected on the main menu is displayed 1 Setting Menu The name of the setting menu currently selected is displayed her...

Страница 26: ...the values manually set for electronic shutter speed SPEED and EX COMP Bright Bright Priority mode The exposure is adjusted automatically using the values manually set for electronic brightness level When you select one from various exposure modes some of the following setting items that are required for the selected mode will appear GAIN Select the gain from the following 0dB 3 6 dB 7 1 dB 10 7 d...

Страница 27: ...se Mode OUTDOOR 5800K Base Mode OPW One Push White Balance The One Push White Balance mode is a fixed white balance mode that may be automatically readjusted only at the request of the user One Push Trigger assuming that a white subject in correct lighting conditions and occupying more than 1 2 of the image is submitted to the camera One Push White Balance data is lost when the power is turned off...

Страница 28: ...articularly important CONTRAST You can adjust the contrast level in the range from 0 00h to 255 FFh The initial setting is 128 80h The smaller the value is the lower the contrast becomes and the larger the value is the higher the contrast becomes PAN TILT ZOOM Menu The PAN TILT ZOOM menu is used to select the pan tilt zoom mode DIGITAL ZOOM Set to DIGITAL ZOOM ON 2X digital zoom is activated You c...

Страница 29: ...a back to Factory Default setting by pressing HOME button to confirm the action All data of the camera that have been set will be deleted RELOAD PRESET 1 When this item is set to ON preset 1 is set to Home position The camera goes to Home position when it is powered on or reset VIDEO FMT You can change the video format SDI HDMI by adjusting this item Select the item press button to choose the vide...

Страница 30: ...Zoom Operation Panning and Tilting 1 Press the POWER switch The camera will turn on and perform the pan tilt reset operation automatically 2 Press the arrow button to pan or tilt thecamera While checking the picture on the screen press the desired arrow button To move the camera in short increments press the button just for a moment To move the camera in long increments press and hold the button T...

Страница 31: ...he LED turns red to activate the Fast Zoom Speed Mode press again to go back to normal Zoom Speed mode Operating Multiple Cameras with the Infrared Remote Controller 1 Set the DIP Switch on the bottom of the camera to the number of camera you want to operate to 1 2 or 3 See bottom DIP Switch setting instruction 2 Press the CAMERA SELECT button on the infrared remote controller that corresponds to ...

Страница 32: ...protocol programming This function allows you to achieve the desired status instantly even without adjusting the following items each time Pan Tilt Position Zoom Position Focus Auto Manual Focus Position AE Mode Shutter control parameters Bright Control Iris control parameters Gain control parameters Exposure Compensation On Off Exposure Level Backlight Compensation On Off White Balance Mode R B G...

Страница 33: ...in POSITION 1 When you are storing or cancelling the settings in one POSITION you cannot call up store or cancel the settings in another POSITION When the menu is displayed on the screen you cannot perform the operation for storing recalling or cancelling the setting Be sure to return to the normal display before starting these operations Changing Resolutions Press the Video Format Switching butto...

Страница 34: ...1 180 1 250 1 350 1 500 1 725 1 1000 1 1500 1 2000 1 3000 1 4000 1 6000 1 10K sec EX COMP OFF ON WHITE BALANCE MODE AUTO INDOOR OUTDOOR OPW ATW USER R GAIN 0 255 B GAIN 0 255 PICTURE SHARPNESS 0 15 EFFECT OFF B W NOISE REDUCTION OFF 1 5 FLIP OFF ON MIRROR OFF ON DE FLICKER OFF ON GAMMA 0 1 WDR OFF ON COLOR 1 15 CONTRAST 0 255 PAN TILT ZOOM DIGITAL ZOOM OFF ON ZOOM RATIO OSD OFF ON ADAPTIVE PT OFF ...

Страница 35: ...35 ...

Страница 36: ...36 www bolintechnology com 2082 TECHNOLOGY LLC dba BOLIN TECHNOLOGY ...

Отзывы: