22
Controlling via VISCA over IP
•
Connect the network port on the camera to the network switch.
•
Set the IP address and other network information appropriately to communicate on your network
•
Connect the VISCA over IP-compatible controller to the network
•
Configure the controller to access the camera’s IP address and VISCA over IP port
•
The IP port within on your control must be set to 52381 to communicate with the camera.
•
Select VISCA protocol on your IP control device.
Recommended way to re-assign the IP address:
1.
Create a local network within which the camera and your PC/Laptop are connected.
2.
Install and run the IP-FINDER tool (You can contact Bolin Technical support team for tool requirements)
3.
The IP-FINDER can find the camera IP address, which is the default :192.168.0.13
4.
Click the search button, select the camera you want to Assign IP address, edit the IP address to the one that matches your
local network credential.
5.
Once the IP address has been changed successfully, you can access the IP camera via your local network.
Note
How to re-assign the IP address to the camera, please refer to user manual Part Two-IP Camera user
guide.
DIP SWITCH SETTINGS
The bottom dip switch is for setting the camera configuration for following items:
1.
Camera ID Address for RS-485 PELCO protocol
2.
Video output / Video color space
3.
RS-232 / RS-422/485 selection
4.
RS-232 / RS-422/485 baud rate
5.
Video resolutions selection
6.
IR remote controller ID
Setting of the BOTTOMDIP Switches
Turn off power to the camera before changing the DIP switch settings.
Power on the camera to have the new Dip Switch setting activated.
From the above list, No.1 Camera ID address and NO.2 Video resolution settings can be set in camera OSD menu as
well. The camera takes either the way of OSD menu setting or the way of bottom DIP switch setting. They override each
other. After the camera is turned on, the camera takes the last setting before it is turned on, either set through the OSD or
bottom DIP switch.
The Bottom DIP Switch Settings
SWI:
Factory Default Setting: ON, OFF, OFF, OFF, OFF, OFF, OFF, ON.
Bit1~3: Camera Address setting for VISCA protocol
Bit4:
Video Output/Video Color Space
Bit5:
Reserve
Bit6:
RS-232/RS-422
Bit7~8:
RS-232/RS-422 Baud Rate
1.
Camera Address setting for VISCA protocol