18
Step 4
Make desired adjustments using the controls described
in "Compressor Settings” on page 18.
Step 5
Select
Enable
to apply the settings to the selected
channel.
Note:
If you want to return to the factory settings, select the
Reset
icon that
appears in the right corner.
Table 7, Compressor Settings
Threshold
Sets the threshold level, which is the point
where the signal activates the compressor
circuit. The range is -135 to +21 dB.
Attack
Sets how fast the compressor turns on
when the audio signal passes the threshold
level. The range is 1 to 500 ms.
Hold
Sets how long the compressor is on after
the signal has fallen below the threshold.
The range is 1 to 500 ms.
Decay
Sets the rate of turn off of the compressor
after the signal is below the threshold.he
range is 0 to 2000 ms.
Knee
Sets how the compressor reacts to signals
once the threshold is reached. Increasing
the knee level decreases the obvious tran-
sition from the uncompressed to the com-
pressed sound. The range is 1 to 100.
Ratio
Sets the compression ratio. For example, if
the ration is set for 6 (6:1), the input signal
must cross the threshold by 6 dB for the
output level to increase by 1 dB. The range
is 1 to 100.