Fault / Error Message 

Possible cause 

Measures

Could not connect the sensor. Failed 
communication to BiSS master, check the 
connected interface.

Cables are not connected correctly.

Please check the cables to the adapter and to the 
sensor.

Another program maybe using the adapter.

Please close any other application that may use 
the adapter. If the problem still exists perform a 
PC restart.

Could not connect the sensor. BiSS 
communication failed. Check wire connection and 
power supply.

Another program maybe using the adapter.

Please close any other application that may use 
the adapter. If the problem still exists perform a 
PC restart.

Not enough power supply for the adapter.

Please make sure that the PC can provide 
enough power on the USB port. If not, you have to 
provide external power.

Contacts are poorly shielded.

Use shielded cables and ensure proper 
contacting.

Install FTDI interface driver.

The adapter driver is not installed.

Please install the corresponding driver to your 
adapter. If the problem still exists a restart maybe 
necessary.

Calibration failed, rotation speed is too slow for 
calibration.

Velocity or duration are not high enough.

Increase velocity or calibration duration.

Calibration failed, rotation speed is too fast for 
calibration. 

Velocity or duration exceed the limits. 

Decrease velocity or calibration duration. 

Calibration succesful but rotation speed is too 
slow to acquire one complete turn.

A full scale calibration was not performed.

This warning can be ignored when the user 
is not using the full scale measurement area. 
Otherwise it is recommended to repeat the 
calibration with higher velocity or higher duration 
and cover all the scale.

Calibration failed, invalid calibration data cycle 
count.

Very noisy environment.

Please make sure that the cables are shielded 
and that there is no interference in your 
application.

The magnetic poles are damaged in some 
places.

Replace the magnetic nonius scale.

Please check the air gap between the sensor and 
the magnetic scale. The air gap must be 0.4 mm.

The sensor position is out of tolerance.

Please verify the air gap and X, Y mechanical 
position of the sensor to match the tolerance 
discussed in installation tolerance.

Please check X, Y position of the sensor on the 
magnetic scale or the optimum calibration.

Nonius calibration failed. Please reposition the 
sensor and press “Retry”.

The sensor position is out of tolerance.

Please verify the air gap and X, Y mechanical 
position of the sensor to match the tolerance 
discussed in installation tolerance. 

Very noisy environment.

Make sure that the cables are shielded and that 
there is no interference in your application.

The magnetic poles of the scale are damaged 
in some places.

Replace the magnetic nonius scale.

Could not connect the sensor. Unable to detect 
the slave. Please connect compatible AKS17.

Wrong sensor.

Make sure that the sensor option matches your 
sensor.

Analog parameters are all 0 and in the error 
textbox you have the following message: “The 
analog electrical phase error is very big. Please 
check the current sensor configurations and 
positions.”

The sensor is badly positioned. The software 
and the sensor cannot calibrate this big error.

Reposition the sensor acording to the datasheet.

Make sure that the master mark on the sensor is 
aligned with the master track on the ring.

You have good analog calibration but bad nonius 
calibration. 

Wrongly aligned sensor to the ring.

Make sure that the master mark on the sensor is 
aligned with the master track on the ring. 

Wrong ring size.

Make sure that the ring matches the “Size” para-
meter.

Содержание AKS16

Страница 1: ...ntent Safety Instructions 2 Electromagnetic Compatibility 3 Intended Use 3 Function and Properties 3 Assembly and Installation 4 Programming Device 4 Configuring the AKS17 Sensing Head 6 Protocol Data...

Страница 2: ...ems such as airplanes etc Risk of pinching There is a risk of getting pinched between the sensing head and the magnetic tape This can lead to injury or mechanical damage Avoid getting with your limbs...

Страница 3: ...f magnetic scales and sensing heads capable of non contact position detection for linear and rotary applications Fields of deployment capital equipment automation medical engineering electrical engine...

Страница 4: ...all or vice versa is a count for the period counter up down counter If signal A is preceding signal B the counter increases If signal B is preceding signal A the counter decreases The Z pulse appears...

Страница 5: ...re the parameters of an AKS17 sensing head can be changed for a successful calibration The software sets the sensing head parameters for the correct master nonius periods 128 127 120 256 255 240 512 5...

Страница 6: ...tory on your Windows PC To install the driver execute the specific program USB_Adapter_00052040_Driver exe Connecting the device for the calibration setup Mount the sensing head correctly per mechanic...

Страница 7: ...OGEN calibration software AKS16 and AKS17 CalibrationGUI Choose AKS17 from the Sensor combo box Choose the desired sensor parameters see technical data sheet for full listing of sensor parameters Plea...

Страница 8: ...scale or both if needed In case of linear calibration the user will be prompt with the countdown window on every iteration The user has to move the magnetic target during the calibration process In l...

Страница 9: ...circle is red and in the textbox to the right the user can see the corresponding error message 3 Nonius calibration Max and Min represent the maximum and minimum percentage value from result regardin...

Страница 10: ...ion to be 1050 Ticks Now the user can enter 239194 Current Position Resolution mod Resolution in the Desired Offset and then click Set The software automatically calculates the smallest possible offse...

Страница 11: ...The sensor should be connected to the PC before saving or loading configurations The connected sensor serial number the product order code and parameter descriptions can be found under Help then Prod...

Страница 12: ...er can freely disconnect the cables and reconnect a new sensor if desired Q How can I choose calibration duration A Calibration duration represents a time variable The duration should cover at least f...

Страница 13: ...e it is recommended to repeat the calibration with higher velocity or higher duration and cover all the scale Calibration failed invalid calibration data cycle count Very noisy environment Please make...

Страница 14: ...manual Rev 1 4 2021 06 16 14 14 EU Declaration of Conformity Acc to EU regulation for Electromagnetic Compatibility 2004 108 EU European Standard for Electromagnetic Compatibility EN 61326 1 2006 EMC...

Отзывы: