TABLE OF CONTENTS (Continued)
Figure
Page
27 Boost Trimpot (DEC/B) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
30 Models 2982, 2983, 2984 Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
31 Models 2987 Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Items Included in this Package:
Bodine Adjustable Frequency Drive, Bodine Series Installation and Operation Manual, Main Speed
Potentiometer Kit with Insulator and Mounting Hardware, Main Speed Potentiometer Terminals
(3 Orange), Motor and AC Line Terminals (5 Blue), 2-Wire and 3-Wire Connector Kit, Status Indicator
Label, Trimpot Adjustment Tool, CE Approved Product Information Card, Warranty Registration Card.
iv
230
VAC
Controls
Suitable
for
use
on
a
circuit
capable
of
delivering
not
more
than
5
kA
RMS
symetrical
amperes,
230
Volts
maximum.
Use
copper
conductors
rated
75°
C.
Suitable
for
operation
in
a
maximum
surrounding
air
temperature
of
40°C.
UL Notice
Reconditioning the Bus Capacitors
If this drive has been in storage for over one year it is necessary to recondition the
power supply bus capacitors. To recondition the bus capacitors, apply the AC
Line, with the drive in the Stop Mode, for a minimum of one hour. Not following
this procedure will cause the bus capacitor to fail.