How to Start/Stop the STP Pump
◇
NEVER connect or disconnect any cables while the power is ON.
◇
NEVER turn the primary power OFF (Switch the breaker "OFF") while
the STP pump is in rotation.
◇
DO NOT release the inlet port flange or outlet port flange into the
atmosphere while the STP pump is in rotation.
7.1 Before
Starting
Operation
After completing installation, piping, leakage test of the STP pump, installation
of the STP control unit, and wiring of cables, the STP pump is ready for start.
Check the following items before starting:
1) Are the STP pump and the STP control unit secured according to the
appropriate method?
2) Is the power cable connected correctly to the power supply?
3) Is the power voltage selected properly?
4) Are the STP connection cable, and other cables securely connected?
Are each terminal and each connector securely locked?
5) Is the serial number of the STP pump the same as that of the STP control
unit?
If they are different, perform the tuning according to Section 9.1, "Tuning."
6) Did you change the STP connection cable length? If you did, perform the
tuning by reference to Section 9.1, "Tuning."
7-1