STP-H803/H1303 Series Instruction Manual
6.4.2
How to Connect the Cables
In
sta
lla
tio
n
◇
Use the STP connection cable that BOC Edwards has specified. The
use of other cables may result in product damage.
◇
When connecting/disconnecting cables, always power OFF the STP
pump (Switch the breaker "OFF").
Failure to do so may result in electric shock or product damage.
◇
With each connector, align the position of the guide key and insert
the pin vertically so as not to bend it.
If the pin is bent, not only may the connector not function normally,
but may make the pins contact, resulting in a malfunction.
◇
Lock and securely tighten each connector and screw.
◇
DO NOT apply voltage to each pin and DO NOT cause any
short-circuiting between pins.
◇
Connect each cable securely. DO NOT place heavy objects on the
cables nor bend them excessively.
Support each cable so as not to apply direct force to the connectors
or terminals.
If any problem occurs in cables, connectors or terminals, the STP
pump may not function normally.
(1) Connecting the STP Connection Cable
Connect the receptacle (socket) side of the STP connection cable to the STP
connector of the STP pump and connect the plug (pin) side to "P.CONNECTOR
X1" of the STP control unit.
(2) Connecting the TMS Connection Cable (for Use with the TMS unit only)
Connect the plug (pin) side of the TMS connection cable to the "TMS X5" of the
TMS control unit.
(3) Connecting the Power (Primary Side) Cable
Connect the power cable to the "AC POWER X2" on the STP control unit rear
panel as shown in Table 6.1.
6-10