WARNING: TURN ELECTRICAL POWER SUPPLY OFF BEFORE
MAKING ELECTRICAL CONNECTIONS. DRYER MUST BE
GROUNDED (EARTHED).
7/8''
(22mm)
3-17/32''
(90mm)
3/4''
(18mm)
Entry Hole
for Between-Wall Wiring
5/8''
(16.5mm)
Entry Point
for Surface Mounted Wiring
8-3/32''
(205mm)
4-17/32''
(115mm)
Mounting Base
C
L
Horizontal
Reference
Horizontal
Reference
3-15/16''
(100mm)
7-7/8''
(200mm)
4-11/32''
(110mm)
Form No. 710-69 Multi Language (Rev. 1-18-18) © 2018 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
Electrical Characteristics
Recommended Mounting Heights
Removal of Cover
Installation of Mounting Base
IMPORTANT SAFETY INSTRUCTIONS
*
READ AND FOLLOW ALL INSTRUCTIONS
**
Electric warm air hand dryer
i
ntended for use in a household environment
by non-expert users. Not suitable for outdoor use.
*** This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
**** If a fault develops disconnect the electrical supply, a qualified
electrician should be called.
*****
SAVE THESE INSTRUCTIONS
5
Model B-710,115V
AC, 15 Amp, 1725 Watts, 60 HZ, Single Phase, cULus listed.
Model B-710E
, 220-240V, 7A, AC 1500-1700 Watts, 50/60 Hz, Single Phase; VDE approved, CE marked.
B-710E is not available in the United
States and Canada.
Installation instructions and template provide information that will assist in the installation of the Bobrick B-710 115V, B-710E 220-240V. Retain
Installation Instruction Sheet for important maintenance instructions and warranty information.
Distance from floor to bottom mounting screw holes of mounting base.
Men's Washrooms ....................................................................................................................................................................46''
(1170mm)
Women's Washrooms ...............................................................................................................................................................44''
(1120mm)
Children's Washrooms, ages 3-9 .............................................................................................................................................32''
(815mm)
Children's Washrooms, ages 9-12 ............................................................................................................................................36''
(915mm)
Children's Washrooms, ages 12-15 ..........................................................................................................................................40''
(1015mm)
Children's Washrooms, ages 15-18 ..........................................................................................................................................44''
(1120mm)
Barrier-Free Design ..................................................................................................................................................................38''
(965mm)
1. Start installation of dryer by
removing cover. Remove three
screws, one from each side and
one from the bottom of the
dryer. Lift the cover from the
mounting base.
1. Hold the Installation Template against the wall in the desired location of the
installed dryer, see recommended mounting heights above.
2. Make sure line on template representing bottom of dryer mounting base is
horizontal and located at the desired height above floor.
3. Mark center of four mounting screw holes and hole for entry of electrical
wiring if electrical supply is concealed in wall and will enter dryer from back
through mounting base.
NOTE:
Surface-mounted electrical supply entry is located in the lower right corner
of the mounting base. Bottom of mounting base has 1/2'' square (13mm) opening in
lower right corner to accommodate connection of electrical conduit.
4. Drill four holes for #10 (M4.8) mounting bolts or screws (not furnished).
5. For masonry walls provide four #10 expansion shields or anchors and secure
with four #10 (M4.8) sheet-metal screws (not furnished). For plaster or dry
wall construction, provide concealed backing to comply with local building
codes and secure with four #10 (M4.8) round-head sheet-metal screws, or
3/16'' (5mm) toggle bolts (not furnished).
NOTE:
Use 2'' (50mm) long screws in top two mounting holes. Use 3'' (75mm) long
screws in lower two mounting holes.
6. Fasten mounting base securely to wall.
*
Bobrick automatic hand dryers should be installed 15" (380mm) above any projection or horizontal surface which may interfere with the
operation of the automatic sensor.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED LICENSED
ELECTRICIAN