12
SFU 0303
Frequency Converter
6.3 19" Version: Mains and Spindle connection
Back side SFU0303-19" with spindle connector clamp terminal
Spindle Connector - 9pin clamp terminal
Mains connection - 3pin clamp terminal:
Spindle connection
Spindle Interface
I/O Interface
Mains Connection
Automatic Fuses
automatic thermal fuse
Pin
Name
Direction
Function
1
+VFP
Output
Auxiliary voltage supply for active speed sensor 12V/50mA
2
SGND
Ground for signals FP, PTC
3
FP
Input
Input for two/three wire-speed sensors
4
PTC/KTY
Input
Temperature signal from spindle or as option KTY
setting on spindle interface Pin1 ->6.6
5
W
Output
Spindle Phase W
6
V
Output
Spindle Phase V
7
U
Output
Spindle Phase U
PE
PE
PE
PE
Connection for protective earth of the spindle
! Safety !
Name
Function
PE
protective earth
! Safety !
N
Neutral
L
Phase
Please ensure, that PE protective earth is connected at the mains side. The device must not
be operated without properly connected PE!
Please ensure, that PE protective earth is connected at the spindle side as well as at the
mains side.
Control wires, Mains cables and spindle cables should be installed separately.
For wiring, the use of shielded cables is recommended.
Содержание SFU 0303/4
Страница 1: ... when it comes to quality BMR GmbH 1 ...
Страница 2: ...2 SFU 0303 Frequency Converter ...
Страница 7: ... when it comes to quality BMR GmbH 5 3 Block Diagram ...
Страница 41: ... when it comes to quality BMR GmbH 39 16 Mechanic Views and Dimension 16 1 SSE Version for cabinet mounting ...
Страница 42: ...40 SFU 0303 Frequency Converter 16 2 19 Version ...
Страница 43: ... when it comes to quality BMR GmbH 41 16 3 Version Desktop ...
Страница 44: ...42 SFU 0303 Frequency Converter 16 4 Version Desktop 63TE ...
Страница 47: ... when it comes to quality BMR GmbH 45 ...
Страница 48: ...46 SFU 0303 Frequency Converter ...