Error Description
Cause
Fixing
Loose connection in spindle,
spindle cable or at the
connectors
> Check spindle cable and exchange
potentially
> Check connectors
Disturbanes on the signal or
the signal amplitude is too
low
> sensor wires in spindle
cable are not shielded
> Exchange spindle cable
> for verification test exchange
spindle
Spindle cable is defective
> Check the 3 spindle phase wires
Spindle cable too long -
With activated spindle test, a
test current is send via
spindle cable to the spindle
by applying a voltage at
output lines. In case that this
current is too low, or a wrong
spindle characteristic
selected, it does not match to
the reference values and the
spindle test fails.
> Check, if the proper characteristic
is selected.
> Increase value for start voltage in
the spindle characteristic
-> contact BMR
> Deactivate function "Spindle test"
With activated speed
sensor:
The spindle runs properly,
but sometimes there
appears the message
Encoder Error.
Error
Without Spindle,
Cable
is desplayed
Содержание SFU 0303/4
Страница 1: ... when it comes to quality BMR GmbH 1 ...
Страница 2: ...2 SFU 0303 Frequency Converter ...
Страница 7: ... when it comes to quality BMR GmbH 5 3 Block Diagram ...
Страница 41: ... when it comes to quality BMR GmbH 39 16 Mechanic Views and Dimension 16 1 SSE Version for cabinet mounting ...
Страница 42: ...40 SFU 0303 Frequency Converter 16 2 19 Version ...
Страница 43: ... when it comes to quality BMR GmbH 41 16 3 Version Desktop ...
Страница 44: ...42 SFU 0303 Frequency Converter 16 4 Version Desktop 63TE ...
Страница 47: ... when it comes to quality BMR GmbH 45 ...
Страница 48: ...46 SFU 0303 Frequency Converter ...