…when it comes to quality!
BMR GmbH
11
6.2 Version SSE: Mains and Spindle connection
View at screw terminals at version SSE:
Pin
Name
Direction Function
1
+VFP
Output
Auxiliary voltage supply for active speed sensor 12V/50mA
2
SGND
Ground reference for signals FP, PTC
3
FP
Input
Input for 2/3-wire speed sensors / Hall sensor
4
PTC
Input
temperture signal of the spindle or as option KTY setting
via interface X4-Pin3 -> 6.3
5
W
Output
Spindle Phase W
6
V
Output
Spindle Phase V X4
7
U
Output
Spindle Phase U
8
Rext
Output
External Brake resistor / Chooper Resistor
9
+ZU
Output
Intermediate voltage (! Attention, High Tension!)
10
PE
Output
Connection for protective earth of spindle
! Safety !
+VFP
SGN
D
FP
PTC
W
V
U
Rext
+ZU
PE
L
N
PE
Name
Function
PE
protective Earth
! Safety
!
N
Null
L
Phase
The device has no internal fusing. It has to be fused externally
Please ensure, that PE protective earth is connected at the mains side. The
device must not be operated without properly connected PE!
Please ensure, that PE protective earth is connected at the spindle side as
well as at the mains side.
Control wires, Mains cables and spindle cables should be installed
separately.
For wiring, the use of shielded cables is recommended.
+VFP
SGND
FP
PTC
W
V
U
Rext
+ZU
PE
PE
N
L
Содержание SFU 0303/4
Страница 1: ... when it comes to quality BMR GmbH 1 ...
Страница 2: ...2 SFU 0303 Frequency Converter ...
Страница 7: ... when it comes to quality BMR GmbH 5 3 Block Diagram ...
Страница 41: ... when it comes to quality BMR GmbH 39 16 Mechanic Views and Dimension 16 1 SSE Version for cabinet mounting ...
Страница 42: ...40 SFU 0303 Frequency Converter 16 2 19 Version ...
Страница 43: ... when it comes to quality BMR GmbH 41 16 3 Version Desktop ...
Страница 44: ...42 SFU 0303 Frequency Converter 16 4 Version Desktop 63TE ...
Страница 47: ... when it comes to quality BMR GmbH 45 ...
Страница 48: ...46 SFU 0303 Frequency Converter ...