15
Figure 8:
Configuring the battery capacity
Figure 9:
Configuring the battery alarm
CONFIGURING BATTERY CAPACITY
The battery capacity needs to be set whenever a new battery is fitted to the J35. By
default, the battery capacity is set to 100AH.
Correctly configuring the battery capacity ensures that the J35 will select the best
charging parameters for the caravan battery in use and the software accurately
estimates battery usage including Battery Capacity and Time Remaining.
Enter Set-Up mode and navigate to the
bat CaP
menu function. Follow the directions
in Figure 8 to configure the battery capacity. The battery capacity can be adjusted
between 50 and 600AH in steps of 10AH.
CONFIGURING BATTERY ALARM
Configure the battery alarm and set the low battery voltage warning threshold to
trigger the Battery Low warning on the JControl Home screen to indicate that the
battery requires charging.
By default, the low voltage warning threshold is 11V.
Enter Set-Up mode and navigate to the
bataLm
menu function. Follow the directions
in Figure 9 to configure the battery alarm. The battery alarm can be adjusted between
10.0 and 14.0V in steps of 0.5V.