Feature
Parameter Parameter
Feature
Detailed
Description
P5
P6
P7
P8
P9
PA
Motor 1
low speed
obstruction
sensitivity
Motor 2
low speed
obstruction
sensitivity
Slow speed
running time
Opening/
Closing
delay time
Main Auto
Closing
Electric lock
output mode
1
...
12
1
...
12
0
1
...
5
0
1
2
...
8
0
1
...
99
0
1
...
6
1 (Most Sensitive)
Factory set 8
12 (slowest)
1 (Most Sensitive)
Factory set 8
12 (slowest)
No slow speed
Shortest
Longest
No delay
1s
Factory Set 2s
8s
Factory Set
1s
....
99s
Not output
(factory set)
1s
...
6s
Soft stop force adjustment
Soft stop force adjustment
This adjusts the ramp down of the gate.
The slow speed can be adjusted (0 not
recommended as this puts extra stress on
moving parts). For long gates we recom-
mend the standard setting of 2.
This setting is for Dual Swing gates. You
can adjust the opening/closing delay
between the two motors. This is required
if you have an electric gate lock connected
to the control board or if you require Motor
2 to open first and Motor 1 to close first.
You can set this from 0 seconds (open and
close at the same time) up to 8 seconds.
Factory setting is 2 seconds and is recom-
mended even if a gate lock is not installed.
Auto close setting can be set from 0
seconds (factory setting) up to 99 seconds.
This setting allows you to adjust the output
to your optional electric gate lock. Factory
setting is 0 which is set for NO GATE
LOCK. If you install a gate lock, it is recom-
mended you set PA to level 3 (3 seconds).
This may need to be adjusted depending on
your gate setup.
If lock output is set 1 to 6, the lock will
activate first for 1 second before the gate
starts, this is to allow time for the lock to
activate.