meM-LOG-SE 

 

 

© BMC Messsysteme GmbH 

 

Page 6 

4  Functions of the pushbutton and states of the LED 

The pushbutton at the front of the device must be pressed to turn the 

meM-LOG-SE

 on or off. Besides that, the 

pushbutton features various functions, depending on how long it is pressed and in which state and operating mode the 
logger is. 

The two LEDs give useful information about the current device status. As soon as the power supply is connected and 
the 

meM-LOG-SE

 is provided externally with power, the green LED is on. In this case, the integrated accumulator is 

charged at the same time. The red LED indicates different states, being on or off or flashing in varying speed or dura-
tion.  

The following table helps to get an overview of the various functions of the pushbutton depending on the current device 
status, of possible settings and the resulting state of the red LED: 

Description of the function 

Press pushbutton for ... 

Device status before 

Status of red LED 

 

turn on device 

[1.5sec;4.5sec] off 

after 

1.5sec LED on (flashing if 

memory empty, shining if data 
available) 

 

turn off device 

at least 5sec 

on 

fast flickering after 0.5sec, after 
5sec LED off 

 

delete memory 
(

Æ

 measuring data deleted, scan 

settings are kept, device ready 
for scan) 

>7sec 

off 

after 1.5sec LED on, after 4.5sec 
fast flashing for app. 2.5sec, then 
slow flashing 

 

start scan 

[0.5sec;5sec[ 

on, flashing LED, de-
vice ready for scan 

fast flashing after 0.5sec, during 
scan short and repeating flashing 

 

end scan  
(

Æ

 turn off device, measuring 

values are saved up until the 
point of turning off) 

at least 5sec 

Scan running, repeated 
and short flashing of 
LED 

fast flickering after 0.5sec, after 
5sec LED off 

 

"Instant On", temporarily inter-
rupt energy-saving mode  

<0.5sec 

Sleep Mode 

not changing 

 

 

If you start a scan with the device button or a digital signal at the digital connector, the memory must be empty. 
This does not apply to the operating software ST-meM-LOG SE, which displays a warning in this case. 

All states of the red LED and their meaning for the current device status is listed below:  

Status of red LED 

Device status 

Indication 

Pushbutton operation 

permanently off 

off 

device turned off or accumulator empty 

Æ

 turn on device, charge accumulator 

turn on device: press pushbutton for 
[0.5sec;4.5sec] 

permanently on 

on, 

Continu-

ous Mode

 

measuring data stored in memory, no scan possible

Æ

 first read out data, delete memory or  

 

change scan configuration before next scan 

delete memory: turn device off and 
on (see above), when turning on 
press pushbutton for >7sec  

permanently on 

on,  

Alarm Mode

Loop Mode 

off 

memory full, no scan possible 

Æ

 first read out data, delete memory or  

 

change scan configuration before next  

 scan 

delete memory: turn device off and 
on (see above), when turning on 
press pushbutton for >7sec 

flashing 

on 

device ready for scan 

Æ

 start scan (if desired) 

start scan: press pushbutton for 
[0.5sec;5sec[ 

repeated and short 
flashing 

on scan 

running 

Æ

 end scan (if desired) 

end scan: press pushbutton for at 
least 5sec 

permanently off 

off 

device turned off or accumulator empty 

Æ

 turn on device, charge accumulator 

turn on device: press pushbutton for 
[0.5sec;4.5sec] 

 

Содержание MEM-LOG-SE

Страница 1: ... it is no problem to realize measuring applications which require mobility and flexibility in a high degree In order to extend the operating time of the accumu lator the device changes into an energy saving mode after 1 minute Sleep Mode and just wakes up occasionally e g shortly before scanning the next measuring value Via 16 analog input channels in the measuring range of 5V with a resolution of...

Страница 2: ...ition and processing measuring files created with ST meM LOG SE can be dis played in NextView 4 as graphic signal curves and then be ana lyzed NextView 4 is also available as a stripped down Analysis version A free demo of the software is included with delivery The instruction set for program ming the meM LOG SE is com patible to the ADAM4000 series For further information please visit our homepag...

Страница 3: ... each channel separately storage of either all channels to be saved or only of channels which are in state of alarm If measuring values are within their normal range again the scan is temporarily interrupted If not in Loop Mode see below the scan continues until memory is full or measurement is stopped even if a scan has been stopped with the device button it can be taken up again the new measurin...

Страница 4: ...listed in the following table Pin Sub D15 meM LOG SE 1 Alarm Out H active high 9 Alarm Out L active low 8 15 Relay contact alarm 3 Digital In 1 active low 11 Digital In 2 active low 12 Scan start active low 5 13 Ground 2 4 6 7 10 14 n c In case of alarm the alarm outputs and the relay contact at pin 1 9 or 8 15 become active at the same time as long as the signal values exceed the defined range Al...

Страница 5: ...ion over great distances connection of a modem 3 3 1 Serial connection RS232 The serial connection requires a 9 pole cross wired null modem cable not electrically isolated which is connected to the two 9 pole Sub D plugs of the logger and the PC to be ordered under ZUKA SER9 The serial connection of the logger is located at the back of the device If your PC only provides a 25 pole serial connectio...

Страница 6: ...scan Æ turn off device measuring values are saved up until the point of turning off at least 5sec Scan running repeated and short flashing of LED fast flickering after 0 5sec after 5sec LED off Instant On temporarily inter rupt energy saving mode 0 5sec Sleep Mode not changing If you start a scan with the device button or a digital signal at the digital connector the memory must be empty This does...

Страница 7: ... was put on user friendliness and reliability Administration of USB and the serial interface in one program The connection between PC and data logger is realized via the serial RS232 as well as the USB interface so that the advantages of both interfaces are available to the user see chapter 3 3 ST meM LOG SE manages both inter faces so that one device or several can be connected to USB and another...

Страница 8: ... possible in all operating modes Store measuring data with different file format When reading out measuring data from the memory of the data logger ST meM LOG SE writes files in txt or lfx file format which can be displayed as table values and analyzed in various programs for word processing Notepad Wordpad Word etc and spreadsheet e g Excel Especially to mention is the storage as an lfx file the ...

Страница 9: ... the software automatically SP2 do not connect with Windows Update Windows 2000 Search for a suitable driver for my device Under Windows Vista no selections have to be made The driver is found and installed automatically upon connection of the hardware because the driver package has been installed on hard disc before For the same reason no additional location needs to be entered for the driver sea...

Страница 10: ...0Hz channel Sampling period 18h 12min 15sec 1sec in steps of sec 10min 55sec 350msec 0 01sec in steps of 1 100 sec Total sampling rate 16Hz 1 6kHz The total sampling rate is the sum of the sampling rates of the individual used channels e g 5 channels à 100Hz 500Hz total sam pling rate The values for accuracy always relate to the respective measuring range Errors might add at worst Digital inputs a...

Отзывы: