meM-LOG-SE
© BMC Messsysteme GmbH
Page 10
8 Important notes for using meM-LOG-SE
•
The device is only suitable for extra-low voltages – please observe the relevant regulations! For reasons relating to
EMC, the device must only be operated with housing closed. ESD voltages at open lines may cause malfunction
during operation. Only use an electrically isolated power supply unit (with CE).
•
For cleaning the device use water and mild detergent only. The device is designed to be maintenance-free.
•
At the 37- and 15-pole Sub-D
socket
signal cables are connected – use shielded cables only. For best possible inter-
ference suppression connect shield at one end only. Close open inputs if necessary.
•
The device ground and the chassis are electrically connected to the chassis of the PC, which is usually also con-
nected to ground. Be sure to avoid ground loops, since they will cause measuring errors!
•
PCs (notebooks), which are not grounded often produce high potentials to earth at the USB socket, so that safe
operation cannot be guaranteed. In this case connect the data logger to earth.
•
The Gain is adjusted to even values. Therefore only 4000 (with 12 Bit) values of the full range of the converter are
used. As a result, the measuring ranges are slightly larger (
±
5.12V) than the indicated measuring ranges, so that
overranges can be recognized. The AD converter of
meM-LOG-SE
has a code noise of up to
±
1 LSB.
•
If the device has not been used for longer (>3 months), the integrated accumulator must be recharged .
•
The device must not be used for safety-relevant tasks. With the use of the product the customer becomes manufac-
turer by law and is therefore completely responsible for the proper installation and use of the product. In the case of
improper use and/or unauthorized interference our warranty ceases and any warranty claim is excluded.
Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly
disposed according to the WEEE directive or can be returned to bmcm at your own expense.
9 Technical data meM-LOG-SE (typical at 20°C, 5V, after 5min)
•
Analog inputs
Channels // Meas. range // Resolution:
16 single-ended //
±
5V // 12 bit (2.5mV)
Abs. accuracy // Noise // Surge protection:
±
5mV //
±
1 LSB // max.
±
35V (on), max.
±
20V (off), max.
±
20mA in total of all input channels!
Input resistance // Input capacity:
1M
Ω
(with Logger turned off: 1k
Ω
) // 5pF
Zero shift // Gain drop:
±
50ppm/
°
C //
±
50ppm/
°
C
Frequency accuracy // Frequency drift:
±
100ppm //
±
50ppm/
°
C
Normal Mode
Fast Mode
Sampling rate:
1.5*10
-5
Hz .. 1Hz / channel
1.5*10
-3
Hz .. 100Hz / channel
Sampling period:
18h 12min 15sec .. 1sec (in steps of sec.)
10min 55sec 350msec .. 0.01sec (in steps of 1/100 sec.)
Total sampling rate*:
16Hz
1.6kHz
* The total sampling rate is the sum of the sampling rates of the individual used channels
(e.g. 5 channels à 100Hz => 500Hz total sam-
pling rate). The values for accuracy always relate to the respective measuring range. Errors might add at worst.
•
Digital inputs and alarm output
Channels // Level // Surge protection:
2 input channels // CMOS level (low: 0V..1V; high: 3V..5V) // max.
±
0.5V, protected with 1k
Ω
Input resistance // Input capacity:
1M
Ω
(with PC turned off: 1k
Ω
) // max. 20pF
Output // Current pick-up digital output:
1 relay output: high-active, low-active // 1mA (with app. 4V level), max. 2.5mA (with app. 3V level)
Relay output:
potential-free relay contact 60V, 1A, response or fall time 10ms, live period >100000 cycles
•
Memory
Storage capacity:
512kB,
Loop Mode
selectable
Required memory:
Continuous Mode
: 2 Bytes/meas. value;
Alarm Mode
: 7 Bytes/meas. value
•
General data
USB interface // Power supply:
USB 2.0 compatible (full speed) // 3-pole DIN plug, 9-45V max. 3W
Accumulator:
operating time: 30h-7weeks (dep. on configuration) // charging time: 3-4h
Serial connection // USB connection:
RS232 interface w. null modem cable (ZUKA-SER9) // on Windows
®
2000/XP/Vista with USB cable
Analog connection // Digital connection:
all channels at a 37-pole // 15-pole Sub-D socket at the front // back of the device
CE standards:
EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF) visit www.bmcm.de
ElektroG // ear registration:
RoHS and WEEE compliant // WEEE Reg.-No. DE75472248
Max. perm. potentials // Protection type:
60V DC acc. to VDE
, max. 1kV ESD on open lines // IP30
Temperature range // Rel. humidity:
-20°C..+50°C // 0-90% (not condensing)
Housing // Delivery:
aluminum housing 167 x 113 x 30 mm
3
// device with aluminum housing, 1m USB connection cable,
"Software Collection" CD with drivers, software and documentation, description
Available accessories:
DIN rail set ZU-SCHI, serial cable ZUKA-SER9 (3m), Sub-D plugs ZUST37, ZUST15, 3-pole socket
ZU3DIN, USB extension cable ZUKA-USB, connecting cables ZUKA37SB, ZUKA37SS, connector
boards ZU37BB, ZU37CB, ZU37CO, power supply ZU-PW10W (required for USB also!)
Guarantee:
2 years with effect from sales date, damages at product resulting from improper use excluded
•
Software support
Software (included):
operating software ST-meM-LOG SE to display and control analog/digital processes; demo software
NextView
®
4 DEMO for graphic display and analysis of signal files
NextView
®
4 Analysis (optional):
software to display signal files and analyze measurement data under Windows
®
2000/XP/Vista
Manufacturer: BMC Messsysteme GmbH. Subject to change due to technical improvements. Errors and printing errors excepted.
Rev. 4.0
03/03/2009