meM-LOG-SE 

 

 

© BMC Messsysteme GmbH 

 

Page 2 

A scan is started by pressing a 
pushbutton, at a defined date, by a 
programming command or by a 
digital signal.  
It is finished either by another 
programming command, by turn-
ing off the device or when the 
storage capacity is reached (not in 

Loop Mode

).  

Afterwards, the measuring data are 
read out and sent to the PC for 
processing.  
 
Unlike the 

Continuous Mode

, you 

can also interrupt a scan in 

Alarm 

Mode 

by turning off the device and 

continuing afterwards. 
 
As a device of the meM-series, the 

meM-LOG-SE

 is provided with a 

USB connection, which means  
 

... high transmission rates  

of the measuring data ... 

 

from the data acquisition system to 
the PC. In addition, the logger 
features a serial connection 
(RS232) so that the device can be 

used together with all operating 
systems supporting the serial inter-
face (even Linux!). That means 
that also  
 

... transmission by modem ... 

 
is possible. 
 
 
If not only voltages are measured 
but other physical quantities with 
sensors, the carrier board 

BP16

 

from BMC Messsysteme GmbH 
supplied with the 

MAL

 miniature 

measuring amplifiers is ideal for 
the combination with the data 
logger.  
This is realized via a 1:1 connec-
tion of the 37-pole Sub-D sockets 
at the front of the two devices.  
Besides that, the 

BP16

 can be 

operated with the external power 
supply provided at the Sub-D 
socket of the logger. 
 
The control of the 

meM-LOG-SE

 

takes place by programming via 
the serial interface or by means of 

the operating software ST-meM-
LOG SE included with delivery.  
Since ST-meM-LOG SE supports 
the same file format as the modern 
software 
 

... NextView

®

4 ... 

 
for data acquisition and 
processing, measuring files created 
with ST-meM-LOG SE can be dis-
played in NextView

®

4 as graphic 

signal curves and then be ana-
lyzed.  
NextView

®

4 is also available as a 

stripped-down "Analysis" version. 
A free demo of the software is 
included with delivery.  
 
The instruction set for program-
ming the 

meM-LOG-SE

 is com-

patible to the ADAM4000 series. 
 
 
For further information please visit 
our homepage at: 
 

U

www.bmcm.de/us

U

 

1  Starting up the device and using the accumulator 

Plug the two red frames onto the short sides of the device with the feet looking downwards as illustrated in the product 
picture.  

The power supply for the device (12V, 12W) is optionally available (

ZU-PW10W

) as accessory. In addition, an accu-

mulator is integrated so that (depending on the load) the 

meM-LOG-SE

 can be operated between 30 hours and 7 

weeks without external power supply. As soon as the external power supply is connected (green LED on), the accumu-
lator is recharged. Charging is done within 3-4 hours approximately even during a scan. Before first use, charge the 
accumulator for about 1 hour. To prevent any loss of data, do not deeply discharge the accumulator. In this case, it has 
to be loaded with the device turned off. To keep the functioning of the accumulator, it should not stay unused for more 
than one year.  

For controlling 

meM-LOG-SE

 and transmitting measuring data, connect the device to the PC with a serial interface 

cable (9-pole null modem cable) or USB cable (included with delivery) depending on the interface you want to use. 

The logger is suitable for DIN rail mounting. The DIN rail set 

ZU-SCHI

 can be ordered optionally. 

If using several measuring systems of the meM series or the amplifier system 

BP16

, the red frames of the device can be 

fit together, so that the devices form a stable unit (see chapter 5). 

Содержание MEM-LOG-SE

Страница 1: ... it is no problem to realize measuring applications which require mobility and flexibility in a high degree In order to extend the operating time of the accumu lator the device changes into an energy saving mode after 1 minute Sleep Mode and just wakes up occasionally e g shortly before scanning the next measuring value Via 16 analog input channels in the measuring range of 5V with a resolution of...

Страница 2: ...ition and processing measuring files created with ST meM LOG SE can be dis played in NextView 4 as graphic signal curves and then be ana lyzed NextView 4 is also available as a stripped down Analysis version A free demo of the software is included with delivery The instruction set for program ming the meM LOG SE is com patible to the ADAM4000 series For further information please visit our homepag...

Страница 3: ... each channel separately storage of either all channels to be saved or only of channels which are in state of alarm If measuring values are within their normal range again the scan is temporarily interrupted If not in Loop Mode see below the scan continues until memory is full or measurement is stopped even if a scan has been stopped with the device button it can be taken up again the new measurin...

Страница 4: ...listed in the following table Pin Sub D15 meM LOG SE 1 Alarm Out H active high 9 Alarm Out L active low 8 15 Relay contact alarm 3 Digital In 1 active low 11 Digital In 2 active low 12 Scan start active low 5 13 Ground 2 4 6 7 10 14 n c In case of alarm the alarm outputs and the relay contact at pin 1 9 or 8 15 become active at the same time as long as the signal values exceed the defined range Al...

Страница 5: ...ion over great distances connection of a modem 3 3 1 Serial connection RS232 The serial connection requires a 9 pole cross wired null modem cable not electrically isolated which is connected to the two 9 pole Sub D plugs of the logger and the PC to be ordered under ZUKA SER9 The serial connection of the logger is located at the back of the device If your PC only provides a 25 pole serial connectio...

Страница 6: ...scan Æ turn off device measuring values are saved up until the point of turning off at least 5sec Scan running repeated and short flashing of LED fast flickering after 0 5sec after 5sec LED off Instant On temporarily inter rupt energy saving mode 0 5sec Sleep Mode not changing If you start a scan with the device button or a digital signal at the digital connector the memory must be empty This does...

Страница 7: ... was put on user friendliness and reliability Administration of USB and the serial interface in one program The connection between PC and data logger is realized via the serial RS232 as well as the USB interface so that the advantages of both interfaces are available to the user see chapter 3 3 ST meM LOG SE manages both inter faces so that one device or several can be connected to USB and another...

Страница 8: ... possible in all operating modes Store measuring data with different file format When reading out measuring data from the memory of the data logger ST meM LOG SE writes files in txt or lfx file format which can be displayed as table values and analyzed in various programs for word processing Notepad Wordpad Word etc and spreadsheet e g Excel Especially to mention is the storage as an lfx file the ...

Страница 9: ... the software automatically SP2 do not connect with Windows Update Windows 2000 Search for a suitable driver for my device Under Windows Vista no selections have to be made The driver is found and installed automatically upon connection of the hardware because the driver package has been installed on hard disc before For the same reason no additional location needs to be entered for the driver sea...

Страница 10: ...0Hz channel Sampling period 18h 12min 15sec 1sec in steps of sec 10min 55sec 350msec 0 01sec in steps of 1 100 sec Total sampling rate 16Hz 1 6kHz The total sampling rate is the sum of the sampling rates of the individual used channels e g 5 channels à 100Hz 500Hz total sam pling rate The values for accuracy always relate to the respective measuring range Errors might add at worst Digital inputs a...

Отзывы: