meM-LOG-SE
© BMC Messsysteme GmbH
Page 8
¾
Continuous Mode, Alarm Modus, Loop Mode ... – and even more
ST-meM-LOG SE supports or even extends all functions integrated in the data logger (see chapter 2). For example
in
Alarm Mode
, you can either save all selected channels or only the ones that exceeded the normal range.
¾
Configuration in one dialog
N
N
E
E
W
W
!
!
All scan settings are directly entered in one dialog.
¾
Offset adjustment
N
N
E
E
W
W
!
!
You can set an offset to calibrate the logger at 0V for each channel separately.
¾
Manual or automatic scan start
In ST-meM-LOG SE, you can start a measurement either by pressing a button or automatically at a certain date and
time making personal presence at scan start unnecessary.
¾
Showing the memory usage
N
N
E
E
W
W
!
!
A progress bar on the user interface continuously indicates the used space of the meM-LOG-SE memory even
during a scan.
¾
Alarm outputs optionally always on
N
N
E
E
W
W
!
!
In
Sleep Mode
, the alarm outputs of the data logger optionally keep their full functionality.
¾
Read out measuring data in the background
Even a measurement, which is still running, can be read out up to the present moment. In
Loop Mode
, the memory
is deleted in this case. Scanning for a long period of time is possible without any loss of data if measuring values are
regularly read out.
N
N
E
E
W
W
!
!
Reading out measuring data during a running scan is now possible in all operating modes.
¾
Store measuring data with different file format
When reading out measuring data from the memory of the data logger,
ST-meM-LOG SE writes files in
*.txt
or
*.lfx
file format, which can be displayed as table values and analyzed in various programs for word processing
(Notepad
®
, Wordpad
®
, Word
®
etc.) and spreadsheet (e.g. Excel
®
). Especially to mention is the storage as an
*.lfx
file, the file format of the professional measuring software NextView
®
4 (free demo version on the "Software Col-
). Here signals runs are graphically displayed and can be processed by means of
extensive analysis functions.
N
N
E
E
W
W
!
!
The conversion from
txt
-format into an
lfx
-file is not necessary anymore. The measuring data are directly
written into the selected file.
7 Software
installation
All the software for Windows
®
2000/XP/Vista and documentation available for
meM-LOG-SE
is inte-
grated on the "Software Collection"-CD included with delivery. When inserting the CD a CD starter opens
automatically (otherwise: start
setup.exe
).
meM-LOG-SE
U
Change to the product page of
meM-LOG-SE
by selecting the entry "Products" in the CD starter and then
the device ("meM-LOG-SE") listed under the interface "USB".
For detailed information about installing or operating the software please see the corresponding manuals. To
open the documentation in PDF format the Adobe Acrobat Reader is required.
You can run any installation directly from CD. If your browser prevents this first save the setup pro-
gram to hard disc before running it separately afterwards.