Functions of the volumetric keypad
The water cooler (VOL model) is equipped with a VOLUMETRIC dispensing
system. The dispensing quantities are easily PROGRAMMABLE during installation.
On turning on the unit, the default settings are as follows: the upper buttons
dispense 200 ml of water (a cupful), whereas the lower buttons dispense 1000 ml
(1 litre).
BUTTON FUNCTIONS:
- SPARKLING WATER DISPENSER button (P.1)
- ROOM-TEMPERATURE WATER DISPENSER button (P.2)
- COLD WATER DISPENSER button (P.3)
SETTING THE QUANTITIES:
Thanks to the Volumetric dispensing functionality, you can customize the pre-set
quantities dispensed by each of the 3 buttons. Normally, a SHORT pressure of the
buttons used for the dispensing of small quantities, with a LONG pressure being
used for the dispensing of larger quantities. The default settings are 200 cc for a
short pressure and 1000 cc (1 litre) for a long pressure.
To enter the programming mode, press and hold (for > 4 seconds) the following
combination of buttons: P.4 + P.2 (Energy Saving “Room temperature”
button). When you enter the programming phase, you will hear three consecutive
beeps.
In this phase, the BLUE led L.1 and the GREEN led L.2 start flashing.
To set the maximum dispensing limit for a specific button, press the button
in question to start the dispensing process and press it again once you have
reached the desired quantity. When the limit for the button has been set, the
BLUE led L.1 stays on. Repeat the process for the remaining buttons.
To exit from the programming mode, press and hold (for > 4 seconds) the
following combination of buttons: P.4 + P.2 (Energy Saving “Room
temperature” button), save the data and set the new limits.
The maximum settable quantity for each button is around 3,0 litres, which equates
to a 65-second dispensing session.
FUNCTIONALITY WITH ALARMS ACTIVATED:
“NO WATER” ALARM:
This alarm is triggered when the pump sends the NO
WATER signal. In this case, the associated BLUE led L.1 starts to flash quickly and
the sparkling water dispensers do not work. The other dispensers continue to
work as normal. To reset the alarm, turn the unit off and back on again.