background image

Pull-out stop

Do not damage 

piercing pins.

Assembly

Blum transformer and accessories

Assembly

SERVO-DRIVE switch

12

Содержание AVENTOS HF

Страница 1: ...Installation instructions Original SERVO DRIVE for AVENTOS AVENTOS HF AVENTOS HS AVENTOS HL AVENTOS HK ...

Страница 2: ...per 8 Distribution cable 8 Drive unit 9 Orientation diagram Blum transformer and accessories 10 Assembly Blum transformer and accessories 11 SERVO DRIVE switch 11 Functions SERVO DRIVE for AVENTOS 13 Start up SERVO DRIVE for AVENTOS 14 Deactivation SERVO DRIVE for AVENTOS 16 LED signals LED displays 16 Assembly Cover cap 17 Replacement SERVO DRIVE switch battery 17 Removal Drive unit 18 Distributi...

Страница 3: ...tal or consequential damages that may arise due to non compliance with these installation instructions Principle Intended use SERVO DRIVE for AVENTOS supports the opening and closing of lift systems in furniture and may only be used under the following conditions In dry enclosed rooms In combination with AVENTOS lift systems from Julius Blum GmbH within per mitted technical specifications In combi...

Страница 4: ... and drive unit Before starting repair or maintenance work unplug the Blum transformer to disconnect the power The drive unit Blum transformer and SERVO DRIVE switch should only be cleaned with a moist cloth because penetrating moisture and aggres sive cleaning materials can damage the electronics of the drive unit Blum transformer and SERVO DRIVE switch Do not touch the area around the lever duri...

Страница 5: ... for electrical appli ances as per local regulations Function Press on the front The lift system opens automatically Press on the SERVO DRIVE switch The lift system closes automatically Manual closing of the lift system by moving it downwards Manual opening of the lift system by moving it upwards Manual use SERVO DRIVE for AVENTOS supports the opening and closing of lift systems in furniture The S...

Страница 6: ...er to the front Planning information Prefered position for distribution cable AVENTOS HF 1 Blum distance bumper Blum distance bumper drilling position For specific applications low front with high weight several bumpers are necessary Bumper must be installed near switch A trial application is recommended From cabinet front edge for fronts that protrude below 6 H 480 549 mm KH x 0 3 28 mm 550 1 040...

Страница 7: ...d for air circulation otherwise there is a risk that the Blum transformer could overheat The dimensions in the drawing take into account the safety distance SERVO DRIVE switch Planning information Cross stabiliser Blum transformer safety distance Cut to size dimension 1 KB KS 16 19 mm 193 mm and or inner width 155 mm 7 AVENTOS HS AVENTOS HL ...

Страница 8: ...stance bumper Lift mechanism Telescopic arm or lever arm Drive unit with LED display Blum transformer with LED display Cover cap Transformer unit housing SERVO DRIVE switch with battery display Distribution cable for cutting to size Connecting node Cable end protector Flex Cabinet Blum distance bumper Front Orientation diagram 8 1 2 3 4 7 5 8 6 9 10 13 11 14 12 ...

Страница 9: ...3 2 1 HF HS HL LOCKED 2 75 Distribution cable Assembly Drive unit Adjustment 9 AVENTOS HF HS HL AVENTOS HK AVENTOS HF HS HL AVENTOS HK ...

Страница 10: ...he completely open position for drive unit installation If required attach the opening angle stop only after drive unit installation and before the reference run NOTICE The drive unit can be locked when the orange slide is no longer visible in the view window NOTICE The drive unit can be locked once it is correctly located on the AVENTOS mechanism 10 AVENTOS HF HS HL AVENTOS HK AVENTOS HF HS HL AV...

Страница 11: ...ccessories Orientation diagram CAUTION Only 1 Blum transformer can be connected to each distribution cable Assembly on the top panel Assembly in combination with SERVO DRIVE for pull out systems Back cabling Upper cabling 11 ...

Страница 12: ...Pull out stop Do not damage piercing pins Assembly Blum transformer and accessories Assembly SERVO DRIVE switch 12 ...

Страница 13: ...onisation Activating collision avoid ance Reset Wireless Reset Motion Start reference run Optional Drive unit SERVO DRIVE switch Reset Motion button Motion LED COLL button SWITCH button Reset Wireless button SYNC button Wireless LED Overview SERVO DRIVE for AVENTOS functions 13 A C D F E B 1 2 3 4 7 5 8 6 9 ...

Страница 14: ...t the reference run see Reset Motion E 1 The reference run restarts Start up SERVO DRIVE for AVENTOS Activating the SERVO DRIVE switch Each switch can only be allocated to one SERVO DRIVE unit Press the SWITCH button until the LED flashes green The drive unit recognises the required parameters using the reference run Operation Lights up continuously Flashes Setting up the wireless connection betwe...

Страница 15: ...here is an activation error reset all drive units see Reset Wireless F 1 Re activate the SERVO DRIVE switch synchronisation and the reference run see A 1 3 C 2 4 and B 1 4 If there is an activation error reset all drive units see Reset Wireless F 1 Re activate the SERVO DRIVE switch collision avoidance and the reference run see A 1 3 D 2 6 and B 1 4 Up to three drive units can be synchronised allo...

Страница 16: ...ompleted successfully Flashes orange quickly Reset Motion confirmation Flashes quickly Press the Reset Motion button using a pen at least 3 seconds until the LED flashes quickly Press the Reset Wireless button using a pen at least 3 seconds until the LED flashes quickly Resets the reference run and enables a new reference run to be started Deactivates all functions All active SERVO DRIVE switches ...

Страница 17: ...ions CAUTION The SERVO DRIVE switch battery must not be recharged or thrown into fire NOTICE If the battery is inserted incorrectly the SERVO DRIVE switch battery display flashes red Please note proper pole connections NOTICE When battery power begins to weaken the SERVO DRIVE switch battery display flashes red Assembly Cover cap Replacement SERVO DRIVE switch battery 17 ...

Страница 18: ...lug the Blum transformer to disconnect the power Never open a Blum transformer There is a danger of electric shock Do not damage piercing pins Removal Removal Blum transformer and accessories Removal Distribution cable Drive unit 18 AVENTOS HF HS HL AVENTOS HK ...

Страница 19: ...r time Blum transformer is not connected to the power outlet Connect the flex to the Blum trans former and to the power outlet Turn on the switched outlet Battery was inserted incorrectly into the SERVO DRIVE switch Battery display on the SERVO DRIVE switch lights red Insert battery correctly Drive unit is not attached properly to the lift mechanism Correctly install drive unit The SERVO DRIVE swi...

Страница 20: ...ode between distribu tion cable and Blum transformer is defective Replace connecting node between distribution cable and Blum transformer Distribution cable is defective Replace distribution cable 2 3 The LED on the Blum transformer does not light Switched outlet is turned off Turn on switched outlet Blum transformer is not connected to the power outlet Connect the flex to the Blum trans former an...

Страница 21: ...emains open in dif ferent positions Start a new reference run Front is warped SERVO DRIVE does not acti vate when pressing on the front Replace front Front is warped and lies on the cabi net on one side Leaning protection is activated Replace front 4 Front does not open or close completely Contents are in the way Remove contents Reference run was interrupted Reset reference run Reset Motion and re...

Страница 22: ...t Motion and restart it Battery was inserted incorrectly LED on the SERVO DRIVE switch lights red Insert battery correctly Battery is dead Replace battery SERVO DRIVE switch is defective Replace SERVO DRIVE switch Drive unit is defective Replace drive unit 6 1 Drive unit has come loose from the lift mechanism Drive unit was not locked completely Lock the drive unit until the locking mechanism snap...

Страница 23: ...n dif ferent positions Start a new reference run 8 Gap forms between SERVO DRIVE switch and cabinet side wall There are chips in the drill hole Remove chips Incorrect drilling dimension used Correct drilling dimension see planning information 9 Two or three fronts open or close in unison Synchronisation was activated in error Deactivate synchronisation 10 Front does not close completely Lift mecha...

Страница 24: ...s and telecommunications equipment 1999 05 EC The following harmonised European standards have been used to ensure proper implementation of the requirements in the EU Directives for the products Z10NE050 xx Z10NE010 xx 21xA0x1 xx 21P5020 xx 21P0020 xx 21 A00L33 xx Z10ZE000 xx The following standard has also been applied for the products Z10NE050 xx and Z10NE010 xx The above products have been test...