Document #: BPI-PM007-01
12
Fault Conditions and Fault Codes
If there are issues with the operation of the Model 450, the onboard diagnostics will indicate the
nature of the problem.
Display Screen codes are shown in
Table 2.
Table 2: Display Screen Status Indicator Fault Codes
Display Color
Display Text
Fault
Operation
Action to Take
Green
Background
Bluezone
Unit conditions
scrolling
System operating
properly.
Operates
None
Yellow
Background
Contact
Bluezone
Fan not rotating, or
Bulb counter failure
Unit automatically
powered down.
Check fan for any
visible obstructions.
Contact Bluezone
Products for
service.
Replace Bulbs,
Unit conditions
scrolling
Bulb life >7,200
hours of operation.
Operates until
8,800 hours of
operation.
Check bulb counter
Order new bulbs
Red Background
Replace Bulbs
Bulb life at 8,800
operation hours.
Unit automatically
powered down until
bulbs replaced and
counter reset.
Replace bulbs and
reset bulb life
counter.
Содержание 450
Страница 4: ...Document BPI PM007 01 3 Key Components Figure 1 Bluezone Model 450 Key Components ...
Страница 9: ...Document BPI PM007 01 8 Figure 6 Rendering of the Bluezone 450 Installed into a Ceiling Mount Kit ...
Страница 12: ...Document BPI PM007 01 11 Figure 8 Display Sequence in Time ...
Страница 20: ...Document BPI PM007 01 19 Figure 12 Remove Bulb Support Wires and Place aside ...
Страница 21: ...Document BPI PM007 01 20 Figure 13 Remove Screws on Bulb Support Clips screws ...
Страница 22: ...Document BPI PM007 01 21 Figure 14 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Страница 23: ...Document BPI PM007 01 22 Figure 15 Remove all Four Old Bulbs by Carefully Pulling on the Ceramic Base ...
Страница 24: ...Document BPI PM007 01 23 Figure 16 Install 4 New Bulbs Do not Touch Bulbs with Bare Hands ...
Страница 25: ...Document BPI PM007 01 24 Figure 17 Install Bulb Clips ...
Страница 26: ...Document BPI PM007 01 25 Figure 18 Install Bulb Support Wires ...
Страница 27: ...Document BPI PM007 01 26 Figure 19 Completed Assembly ...