Document #: BPI-PM007-01
16
Service
BULBS NEED TO BE REPLACED AFTER 8,800 HOURS OF USE. BULB KITS MUST BE
PURCHASED DIRECTLY FROM BLUEZONE PRODUCTS OR AN AUTHORIZED PARTNER
AS THEY ARE
PROPRIETARY BULBS.
Bulbs must be replaced at 8,800 hours of
operation. The display screen reads bulb
hours of operation remaining. At 1,600
hours remaining the display screen will turn
yellow and read “Replace Bulbs.” The bulbs
should be ordered and replaced
immediately. At 0 hours remaining, the
display screen will turn red and the unit will
automatically be powered
OFF
until bulbs
are replaced.
After bulbs are replaced, the bulb counter
needs to be reset. To reset the bulb counter
please follow the steps below.
1) Press and hold the bulb counter
reset button for 3 seconds. The
display screen will read “Hold: reset
counter” during the 3 second hold.
2) After holding for 3 seconds, the
display screen will read “push to
confirm.” Release button and push
to confirm reset.
A bulb replacement kit and instructions can
be ordered from Evo America. The Lamp
Replacement Kit for the Bluezone Model
450 is: 005-000004.
Please call 781-937-0202 or email
[email protected] for ordering
information.
IMPORTANT:
Each bulb kit satisfies
replacement parts for 1 unit. The four bulbs
in each replacement kit cannot be replaced
with bulbs purchased from anywhere, but
Bluezone Products or an Authorized
Partner. Installation of the incorrect bulbs
results in a voided warranty. Purchase of
bulbs from an outside vendor results in a
voided warranty. Bluezone will not operate
correctly with bulbs purchased from outside
vendors.
Service Kit includes:
•
(4) U-shaped bulbs
•
(2) Nitrile gloves
•
Extra cover screws
Additional tools needed:
•
¼” hex nut driver
Содержание 450
Страница 4: ...Document BPI PM007 01 3 Key Components Figure 1 Bluezone Model 450 Key Components ...
Страница 9: ...Document BPI PM007 01 8 Figure 6 Rendering of the Bluezone 450 Installed into a Ceiling Mount Kit ...
Страница 12: ...Document BPI PM007 01 11 Figure 8 Display Sequence in Time ...
Страница 20: ...Document BPI PM007 01 19 Figure 12 Remove Bulb Support Wires and Place aside ...
Страница 21: ...Document BPI PM007 01 20 Figure 13 Remove Screws on Bulb Support Clips screws ...
Страница 22: ...Document BPI PM007 01 21 Figure 14 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Страница 23: ...Document BPI PM007 01 22 Figure 15 Remove all Four Old Bulbs by Carefully Pulling on the Ceramic Base ...
Страница 24: ...Document BPI PM007 01 23 Figure 16 Install 4 New Bulbs Do not Touch Bulbs with Bare Hands ...
Страница 25: ...Document BPI PM007 01 24 Figure 17 Install Bulb Clips ...
Страница 26: ...Document BPI PM007 01 25 Figure 18 Install Bulb Support Wires ...
Страница 27: ...Document BPI PM007 01 26 Figure 19 Completed Assembly ...