5) Look inside the unit and check if there is no debris or scale residue. If
necessary, repeat steps 2-4.
6) Re install the cell into the PVC return pipe.
Note: If you do not currently have a cleaning cap or cleaning rack, you
can fully immerse the cell in a five-gallon bucket.
ALWAYS POUR ACID INTO WATER-NEVER POUR WATER INTO ACID.
BE SURE TO WEAR PROTECTIVE GLASSES, CLOTHING, AND CHEMICAL
RESISTANT GLOVES.
INSTALLATION
Before installation, make sure all the water chemistry is in normal
range.
Using 2-inch pipes and should be performed by qualified personnel in
case there is a 1.5-inch pipe, a reducer can be used to fit the system;
be sure to pay attention to any changes.
Check each measurement carefully before cutting.
Mounting the BLH Control
Install the control box as close as possible to the pump and filter system.
For safety reasons, please do not install the control box within 10 feet of
the edge of the pool and comply with all applicable regulations. Verify
cell and flow switch cable can reach the control box.
As with most electronic devices, avoid using the controller above the
heater or in a tightly enclosed or insulated space can avoid excessive
heat accumulation and also avoid being close to acid chemicals, it may
damage the control.
Use screws to fix the mounting bracket of the control box on the wall or