![Blueworks BLH Series Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/blueworks/blh-series/blh-series_important-safety-instructions-manual_2778734028.webp)
28 |
P a g e
"NO FLOW" light is
blinking
Start the machine, it is
normal that the light blink
because it need time to
detect the water flow
Normal
Variable speed
pump,water flow too slow
Change the flow switch
"Inspect Cell" light
is flashing
The machine worked
around 500 hours
Press the "System Status"
button for 3 seconds to
stop
"Generating" light
is flashing
Check the temperature in
the swimming pool is
whether too high or too
low
Check the temperature,
water temp should be
above 55°F,less than
122°F
"Check Salt" and
"Inspect Cell" light
on
Check cell type
Match the right cell type
with the program
If use variable speed
pump,water flow too slow
Speed up the water flow
Actual Salinity is less
than 2300PPM
Add salt,ideal salt level
3500-3600ppm
Cell is blocked
Clean the cell
Temperature sensor is
broken
If not, replace flow switch
with a temperature sensor
PCB or cell may is
broken
Contact distributor
Содержание BLH Series
Страница 1: ...1 P a g e ...
Страница 12: ...12 P a g e Adding Salt POUNDS and Kg OF SALT NEEDED FOR 3400 PPM ...
Страница 21: ...21 P a g e Overview ...